| Product Class | Maximum Energy Use (kWh/year)* Equation |
| 1. Refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost |
7.99AV + 225.0 0.282av+ 225.0 |
| 1A. All-refrigerators -- manual defrost |
6.79AV + 193.6 0.24av + 193.6 |
| 2. Refrigerator-freezers—partial automatic defrost |
7.99AV + 225.0 0.282av+ 225.0 |
| 3. Refrigerator-freezers—automatic defrost with top-mounted freezer without an automatic icemaker |
8.07AV + 233.7 0.285av + 233.7 |
| 3-Bl. Built-in refrigerator-freezers---automatic defrost with top-mounted freezer without an automatic icemaker |
9.15AV + 264.9 0.323av + 264.9 |
| 3l. Refrigerator-freezers---automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service |
8.07AV + 317.7 0.285av + 317.7 |
| 3l-Bl Built-in refrigerator-freezers--automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service |
9.15AV + 348.9 0.323av + 348.9 |
| 3A. All refrigerators—automatic defrost |
7.07AV + 201.6 0.25av + 201.6 |
| 3A-Bl. Built-in All refrigerators—automatic defrost |
8.02AV + 228.5 0.283av + 228.5 |
| 4. Refrigerator-freezers--automatic defrost with side-mounted freezer without an automatic icemaker |
8.51AV + 297.8 0.301av + 297.8 |
| 4-Bl. Built-in refrigerator-freezers automatic defrost with side-mounted freezer without an automatic icemaker |
10.22AV + 357.4 0.361av + 357.4 |
| 4l. Refrigerator-freezers automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service |
8.51AV + 381.8 301av + 381.8 |
| 4l-Bl. Built-in refrigerator-freezers automatic defrost with side-mounted freezer with an automatic ice maker without through-the-door ice service |
10.22AV + 441.4 0.361av + 441.4 |
| 5. Refrigerator-freezers automatic defrost with bottom-mounted freezer without an automatic icemaker |
8.85AV + 317.0 0.312av + 317.0 |
| 5-Bl. Built-in refrigerator-freezers automatic defrost with bottom-mounted freezer without an automatic icemaker |
9.40AV + 336.9 0.332av + 336.9 |
| 5l. Refrigerator-freezers automatic defrost with bottom-mounted freezer without an automatic icemaker without through-the-door ice service. |
8.85AV + 401.0 0.312av + 401.0 |
| 5l-Bl. Built-in refrigerator-freezers automatic defrost with bottom-mounted freezer without an automatic icemaker without through-the-door ice service. |
9.40AV + 420.9 0.332av + 420.9 |
| 5A. Refrigerator-freezer automatic defrost with bottom-mounted freezer with through-the-door ice service. |
9.25AV + 475.4 0.327av + 475.4 |
| 5A-Bl. Built-in refrigerator-freezers automatic defrost with bottom-mounted freezer with through-the-door ice service. |
9.83AV + 499.9 0.347av + 499.9 |
| 6. Refrigerator-freezers automatic defrost with top-mounted freezer with through-the-door ice service. |
8.40AV + 385.4 0.297av + 385.4 |
| 7. Refrigerator-freezers automatic defrost with side-mounted freezer with through-the-door ice service. |
8.54AV + 432.8 0.302av + 432.8 |
| 7-Bl. Built-in refrigerator-freezers automatic defrost with side-mounted freezer with through-the-door ice service. |
10.25AV + 502.6 0.362av + 502.6 |
| 8. Upright freezers with manual defrost |
5.57AV + 193.7 0.197av + 193.7 |
| 9. Upright freezers with automatic defrost without an automatic icemaker |
8.62AV + 228.3 0.305av + 228.3 |
| 9l. Upright freezers with automatic defrost with an automatic icemaker |
8.62AV + 312.3 0.348av + 260.9 |
| 9-Bl. Built-in upright freezers with automatic defrost without an automatic icemaker |
9.86AV + 260.9 0.348av + 260.9 |
| 9l-Bl. Built-in upright freezers with automatic defrost with an automatic icemaker |
9.86AV + 344.9 0.348av + 344.9 |
| 10. Chest freezers and all other freezers except compact freezers |
7.29AV + 107.8 0.257av + 107.8 |
| 10A. Chest freezers with automatic defrost |
10.24AV + 148.1 0.362av + 148.1 |
| 11. Compact refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost |
9.03AV + 252.3 0.319av + 252.3 |
| 11A. Compact all refrigerators---manual defrost |
7.84AV + 219.1 0.277av + 219.1 |
| 12. Compact refrigerator-freezers--partial automatic defrost |
5.91AV + 335.8 0.209av + 335.8 |
| 13. Compact refrigerator-freezers--automatic defrost with top-mounted freezer |
11.80AV + 339.2 0.417av + 339.2 |
| 13l. Compact refrigerator-freezers--automatic defrost with top-mounted freezer with an automatic icemaker |
11.80AV + 423.2 0.417av + 423.2 |
| 13A. Compact all refrigerators---automatic defrost |
9.17AV + 259.3 0.324av + 259.3 |
| 14. Compact refrigerator-freezers--automatic defrost with side-mounted freezer |
6.82AV + 456.9 0.241av + 456.9 |
| 14l. Compact refrigerator-freezers--automatic defrost with side-mounted freezer with an automatic icemaker |
6.82AV + 540.9 0.241av + 540.9 |
| 15. Compact refrigerator-freezers--automatic defrost with bottom-mounted freezer |
11.80AV +339.2 0.417av + 339.2 |
| 15l. Compact refrigerator-freezers--automatic defrost with bottom-mounted freezer with an automatic icemaker |
11.80AV + 423.2 0.417av + 423.2 |
| 16. Compact upright freezers with manual defrost |
8.65AV + 225.7 0.306av + 225.7 |
| 17. Compact upright freezers with automatic defrost |
10.17AV + 351.9 0.359av + 351.9 |
| 18. Compact chest freezers |
9.25AV + 136.8 0.327av + 136.8 |
*AV = Adjusted total Volume, Expressed in ft3, as determined in 10 C.F.R. sections 430.23(a) (Appendix A to subpart B of part 430) and 430.23(b) (Appendix B to subpart B of part 430) *av = Adjusted total volume, expressed in Liters. | |
(B) Miscellaneous refrigeration products. The energy standards as determined by the equations shown in Table A-3 shall be rounded off to the nearest kWh per year. If the equation calculation is halfway between the nearest two kWh per year values, the standard shall be rounded up to the higher of these values.
- Coolers manufactured on or after October 28, 2019 shall have Annual Energy Use (AEU) not more than the applicable values shown in Table A-3.
| Product Class | Maximum Annual Energy Use (AEU) (kWh/Year) |
| Coolers | |
| Built-in Compact Cooler | 7.88Av + 155.8 |
| Built-in Cooler | |
| Freestanding Compact Cooler | |
| Freestanding Cooler | |
| Combination Coolers | |
| Combination Cooler with all refrigerator-automatic defrost | 4.57AV + 130.4 |
| Built-in combination cooler with all refrigerator-automatic defrost | 5.19AV + 147.8 |
| Combination Cooler with upright freezers with automatic defrost without an automatic icemaker | 5.58AV + 147.7 |
| Built-in combination cooler with upright freezer with automatic defrost without an automatic icemaker | 6.38AV + 168.8 |
| Combination Cooler with upright freezer with automatic defrost with an automatic icemaker | 5.58AV + 231.7 |
| Built-in combination cooler with upright freezer with automatic defrost with an automatic icemaker | 6.38AV + 252.8 |
| Compact combination cooler with all refrigerator-automatic defrost | 5.93AV + 193.7 |
| Built-in compact combination cooler with all refrigerator-automatic defrost | 6.52AV + 213.1 |
| AV= Adjusted total volume, expressed in ft3, as calculated according to 10 C. F. R. Appendix A to subpart B of part 430. | |
(A) The daily energy consumption (in kilowatt hours per day) of each commercial refrigerator and commercial freezer manufactured on or after March 27, 2017 shall be not greater than the applicable values shown in Tables A-4, A-5, and A-6.
| Equipment Category | Condensing Unit Configuration | Equipment Family |
Rating Temperature (°F) |
Operating Temperature (°F) |
Equipment Class Designation* | Maximum Daily Energy Consumption (kWh) |
| Refrigerators and Freezers | Self Contained (SC) | Vertical Closed Transparent (VCT) |
38 (M) 0 (L) |
≥ 32 < 32 |
VCT, SC, M VCT, SC, L |
0.1 × V + 0.86 0.29 × V + 2.95 |
| Vertical Closed Solid (VCS) |
38 (M) 0 (L) |
≥ 32 < 32 |
VCS, SC, M VCS, SC, L |
0.05 × V + 1.36 0.22 × V + 1.38 | ||
| Horizontal Closed Transparent (HCT) |
38 (M) 0 (L) |
≥ 32 < 32 |
HCT, SC, M HCT, SC, L |
0.06 × V + 0.37 0.08 × V + 1.23 | ||
| Horizontal Closed Solid (HCS) |
38 (M) 0 (L) |
≥ 32 < 32 |
HCS, SC, M HCS, SC, L |
0.05 × V + 0.91 0.06 × V + 1.12 | ||
| Service Over Counter (SOC) |
38 (M) 0 (L) |
≥ 32 < 32 |
SOC, SC, M SOC, SC, L |
0.51 x TDA + 1.0 1.10 × TDA + 2.10 | ||
| Refrigerators with transparent doors | Self Contained (SC) | Pull Down PD) | 38 (P) | ≥ 32 | PD, SC, M | 0.11 × V + 0.81 |
| Refrigerators and Freezers without Doors | Self Contained (SC) | Vertical Open (VOP) |
38 (M) 0 (L) |
≥ 32 < 32 |
VOP, SC, M VOP, SC, L |
1.69 × TDA + 4.71 4.25 × TDA +11.82 |
| Semivertical Open (SVO) |
38 (M) 0 (L) |
≥ 32 < 32 |
SVO, SC, M SVO, SC, L |
1.7 × TDA + 4.59 4.26 × TDA +11.51 | ||
| Horizontal Open (HZO) |
38 (M) 0 (L) |
≥ 32 < 32 |
HZO, SC, M HZO, SC, L |
0.72 × TDA + 5.55 1.9 × TDA + 7.08 | ||
| Condensing Unit Configuration, Equipment Family, and Rating Temperature (°F) columns to the left. | ||||||
Table A-5 Standards for Commercial Refrigerators and Freezers with a Remote Condensing Unit That are Not Commercial Hybrid Units
| Equipment Category | Condensing Unit Configuration | Equipment Family | Rating Temperature (°F) | Operating Temperature (°F) | Equipment Class Designation* | Maximum Daily Energy Consumption (kWh) |
| Refrigerators and Freezers | Remote (RC) | Vertical Open (VOP) |
38 (M) 0 (L) |
≥ 32 < 32 |
VOP, RC, M VOP, RC, L |
0.64 × TDA + 4.07 2.20 × TDA + 6.85 |
| Semivertical Open (SVO) |
38 (M) 0 (L) |
≥ 32 < 32 |
SVO, RC, M SVO, RC, L |
0.66 × TDA + 3.18 2.20 × TDA + 6.85 | ||
| Horizontal Open (HZO) |
38 (M) 0 (L) |
≥ 32 < 32 |
HZO, RC, M HZO, RC, L |
0.35 × TDA + 2.88 0.55 × TDA + 6.88 | ||
| Vertical Closed Transparent (VCT) |
38 (M) 0 (L) |
≥ 32 < 32 |
VCT, RC, M VCT, RC, L |
0.15 × TDA + 1.95 0.49 × TDA + 2.61 | ||
| Horizontal Closed Transparent (HCT) |
38 (M) 0 (L) |
≥ 32 < 32 |
HCT, RC, M HCT, RC, L |
0.16 × TDA + 0.13 0.34 × TDA + 0.26 | ||
| Vertical Closed Solid (VCS) |
38 (M) 0 (L) |
≥ 32 < 32 |
VCS, RC, M VCS, RC, L |
0.10 × V + 0.26 0.21 × V + 0.54 | ||
| Horizontal Closed Solid (HCS) |
38 (M) 0 (L) |
≥ 32 < 32 |
HCS, RC, M HCS, RC, L |
0.10 × V + 0.26 0.21 × V + 0.54 | ||
|
Service Over Counter (SOC) |
38 (M) 0 (L) |
≥ 32 < 32 |
SOC, RC, M SOC, RC, L |
0.44 × TDA + 0.11 0.93 × TDA + 0.22 | ||
| Condensing Unit Configuration, Equipment Family, and Rating Temperature (°F) columns to the left. | ||||||
(B) The daily energy consumption (in kilowatt hours per day) of commercial ice cream freezer that are not commercial hybrid units and that are manufactured on or after March 27, 2017, shall be not greater than the applicable values shown in Table A‐6.
| Equipment Family | Condensing Unit Configuration | Equipment Class Designation1 | Maximum Daily Energy Consumption (kWh)2 |
| Vertical Open (VOP) | Remote (RC) Self‐Contained (SC) |
VOP, RC, I VOP, SC, I |
2.79 × TDA + 8.7 5.40 × TDA +15.02 |
| Semivertical Open (SVO) | Remote (RC) Self‐Contained (SC) |
SVO, RC, I SVO, SC, I |
2.79 × TDA + 8.7 5.41 × TDA +14.63 |
| Horizontal Open (HZO) | Remote (RC) Self‐Contained (SC) |
HZO, RC, I HZO, SC, I |
0.7 × TDA + 8.74 2.42 × TDA + 9 |
| Vertical Closed Transparent (VCT) | Remote (RC) Self‐Contained (SC) |
VCT, RC, I VCT, SC, I |
0.58 × TDA + 3.05 0.62 × TDA + 3.29 |
| Horizontal Closed Transparent (HCT) | Remote (RC) Self‐Contained (SC) |
HCT, RC, I HCT, SC, I |
0.4 × TDA + 0.31 0.56 × TDA + 0.43 |
| Vertical Closed Solid (VCS) | Remote (RC) Self‐Contained (SC) |
VCS, RC, I VCS, SC, I |
0.25 × V + 0.63 0.34 × V + 0.88 |
| Horizontal Closed Solid (HCS) | Remote (RC) Self‐Contained (SC) |
HCS, RC, I HCS, SC, I |
0.25 × V + 0.63 0.34 × V + 0.88 |
| Service Over Counter (SOC) | Remote (RC) Self‐Contained (SC) |
SOC, RC, I SOC, SC, I |
1.09 × TDA + 0.26 1.53 × TDA + 0.36 |
|
1 The meaning of the letters in this column is indicated in the Condensing Unit Configuration, Equipment Family and Rating Temperature (oF) columns to the left, and where “I” respresents “ice cream freezer.” 2 Based on Rating Temperature ‐15°F and Operating Temperature ≤ ‐5°F. | |||
(C) Commercial refrigeration equipment with two or more compartments. For commercial refrigeration equipment with two or more compartments, (i.e., hybrid refrigerators, hybrid freezers, hybrid refrigerator‐freezers, and non‐hybrid refrigerator‐freezers), the maximum daily energy consumption (MDEC) for each model shall be the sum of the MDEC values for all of its compartments. For each compartment, measure the TDA or volume of that compartment, and determine the appropriate equipment class based on that compartment’s equipment family, condensing unit configuration, and designed operating temperature. The MDEC limit for each compartment shall be the calculated value obtained by entering that compartment’s TDA or volume into the standard equation in Table A-4, Table A-5 or Table A-6 of this Article for that compartment’s equipment class. Measure the calculated daily energy consumption (CDEC) or total daily energy consumption (TDEC) for the entire case as described in 10 C.F.R. section 431.66(d)(2)(i) through(iii), except that where measurements and calculations reference ARI Standard 1200-2006, AHRI Standard 1200 (I-P)-2010 shall be used.
(D) Wedge Cases. For remote‐condensing and self‐contained wedge cases, measure the CDEC or TDEC according to the ARI Standard 1200 (I-P)-2010 test procedure incorporated by reference in 10 C.F.R. section 431.63. For wedge cases in equipment classes for which a volume metric is used, the MDEC shall be the amount derived from the appropriate standards equation in Table A-4, Table A-5, or Table A-6 of this Article. For wedge cases of equipment classes for which a TDA metric is used, the MDEC for each model shall be the amount derived by incorporating into the standards equation in Table A-4, Table A-5, or Table A-6 of this Article for the appropriate equipment class a value for the TDA that is the product of:
1. The vertical height of the air-curtain (or glass in a transparent door), and
2. The largest overall width of the case, when viewed from the front.
Exception: to Section 1605.1(a)(2) of this Article: The standards shown in section 1605.1(a)(2) of this Article do not apply to salad bars, buffet tables, chef bases, or griddle stands.
(A) Cube Type. Each cube type automatic commercial ice maker with capacities between 50 and 2500 pounds per 24-hour period and is manufactured on or after January 1, 2010, and before January 28, 2018, shall meet the standard levels set forth in Table A-7.
Standards for Cube Type Automatic Commercial Ice Makers
Manufactured on or After January 1, 2010 and Before January 28, 2018
| Equipment type | Type of cooling | Harvest rate (lbs ice /24 hours) |
Maximum energy use (kWh/100 lbs ice) | Maximum condenser water use* (gal/100 lbs ice) |
| Ice Making Head | Water | < 500 | 7.80–0.0055H | 200–0.022H. |
| ≥ 500 and < 1436 | 5.58–0.0011H | 200–0.022H. | ||
| ≥ 1436 | 4.0 | 200–0.022H. | ||
| Ice Making Head | Air | < 450 | 10.26–0.0086H | Not applicable. |
| ≥ 450 | 6.89-0.0011H | Not applicable. | ||
| Remote Condensing (but not remote compressor) | Air | < 1000 | 8.85–0.0038H | Not applicable. |
| ≥ 1000 | 5.1 | Not applicable. | ||
| Remote Condensing and Remote Compressor) | < 934 | 8.85–0.0038H | Not applicable. | |
| ≥ 934 | 5.3 | Not applicable. | ||
| Self Contained | Water | < 200 | 11.40-0.019H | 191–0.0315H. |
| ≥ 200 | 7.6 | 191–0.0315H. | ||
| Self Contained | Air | < 175 | 18.0–0.0469H | Not applicable. |
| ≥ 175 | 9.8 | Not applicable. | ||
|
H) Harvest rate in pounds per 24 hours. *Water use is for the condenser only and does not include potable water used to make ice. | ||||
(B) Batch Type. Each batch type automatic commercial ice maker with capacities between 50 and 4000 pounds per 24-hour period and is manufactured on or after January 28, 2018, shall meet the standard levels set forth in Table A-8.
1. Batch type automatic commercial ice makers include cube type automatic commercial ice makers for purposes of the standards for models manufactured on or after January 28, 2018.
Standards for Batch Type Automatic Commercial Ice Makers
Manufactured on or After January 28, 2018
| Equipment type | Type of cooling |
Harvest rate (lbs ice/24 hours) |
Maximum energy use (kWh/100 lbs ice) | Maximum condenser water use* (galloons/100 lbs ice) |
|---|---|---|---|---|
| Ice Making Head | Water | ≥ 50 and < 300 | 6.88-0.0055H | 200–0.022H. |
| ≥ 300 and < 850 | 5.80–0.00191H | 200–0.022H. | ||
| ≥ 850 and < 1500 | 4.42-0.00028H | 200–0.022H. | ||
| ≥ 1500 and < 2500 | 4.0 | 200–0.022H. | ||
| ≥2500 and < 4000 | 4.0 | 145. | ||
| Air | ≥ 50 and < 300 | 10-0.01233H | Not applicable. | |
| ≥ 300 and < 850 | 7.05-0.0025H | Not applicable. | ||
| ≥ 850 and < 1500 | 5.55-0.00063H | Not applicable. | ||
| ≥ 1500 and < 4000 | 4.61 | Not applicable. | ||
| Remote Condensing (but not remote compressor) | Air | ≥ 50 and < 988 | 7.97-0.00342H | Not applicable. |
| ≥ 988 and < 4000 | 4.59 | Not applicable. | ||
| Remote Condensing and Remote Compressor | ≥ 50 and < 930 | 7.97-0.00342H | Not applicable. | |
| ≥ 930 and < 4000 | 4.79 | Not applicable. | ||
| Self-Contained | Water | ≥ 50 and < 200 | 9.5-0.019H | 191–0.0315H. |
| ≥ 200 and < 2500 | 5.7 | 191–0.0315H. | ||
| ≥ 2500 and < 4000 | 5.7 | 112 | ||
| Air | ≥ 50 and < 110 | 14.79-0.0469H | Not applicable. | |
| ≥ 110 and < 200 | 12.42-0.02533H | Not applicable. | ||
| ≥ 200 and < 4000 | 7.35 | Not applicable. | ||
|
H) Harvest rate in pounds per 24 hours. *Water use is for the condenser only and does not include potable water used to make ice. | ||||
(C) Continuous Type. Each continuous type automatic commercial ice maker with capacities between 50 and 4,000 pounds per 24-hour period manufactured on or after January 28, 2018, shall meet the standard levels set forth in Table A-9.
Standards for Continuous Type Automatic Commercial Ice Makers
Manufactured on or After January 28, 2018
| Equipment type | Type of cooling |
Harvest rate (lbs. ice/24 hours) |
Maximum energy use (kWh/100 lbs. ice) |
Maximum condenser water use* (gal/100 lbs ice) |
| Ice Making Head | Water | ≥ 50 and < 801 | 6.48-0.00267H | 180-0.0198H. |
| ≥ 801 and < 2500 | 4.34 | 180-0.0198H. | ||
| ≥ 2500 and < 4000 | 4.34 | 130.5 | ||
| Air | ≥ 50 and < 310 | 9.19-0.00629H | Not applicable. | |
| ≥310 and < 820 | 8.23-0.0032H | Not applicable. | ||
| ≥820 and < 4000 | 5.61 | Not applicable. | ||
| Remote Condensing (but not remote compressor) | Air | ≥ 50 and < 800 | 9.7-0.0058H | Not applicable. |
| ≥ 800 and < 4000 | 5.06 | Not applicable. | ||
| Remote Condensing and Remote Compressor | ≥ 50 and < 800 | 9.9-0.0058H | Not applicable. | |
| ≥ 800 and < 4000 | 5.26 | Not applicable. | ||
| Self-Contained | Water | ≥ 50 and < 900 | 7.6-0.00302H | 153-0.0252H. |
| ≥ 900 and < 2500 | 4.88 | 153-0.0252H. | ||
| ≥ 2500 and < 4000 | 4.88 | 90 | ||
| Air | ≥ 50 and < 200 | 14.22-0.03H | Not applicable. | |
| ≥ 200 and < 700 | 9.47-0.00624H | Not applicable. | ||
| ≥ 700 and < 4000 | 5.1 | Not applicable. | ||
|
H) Harvest rate in pounds per 24 hours. *Water use is for the condenser only and does not include potable water used to make ice. | ||||
(A) have automatic door closers that firmly close all walk‐in doors that have been closed to within one inch of full closure, except that this subparagraph shall not apply to doors wider than three feet nine inches or taller than seven feet;
(B) have strip doors, spring hinged doors, or other method of minimizing infiltration when doors are open;
(C) contain wall, ceiling, and door insulation of at least R‐25 for coolers and R‐32 for freezers, except that this subparagraph shall not apply to:
1. glazed portions of doors nor to structural members; and
2. A walk-in cooler or walk-in freezer component if the component manufacturer has demonstrated to the satisfaction of the Secretary in a manner consistent with applicable requirements that the component reduces energy consumption at least as much as if such insulation requirements of Section 1605.1(a)(4)(C) of this Article were to apply.
(D) contain floor insulation of at least R‐28 for freezers;
(E) for evaporator fan motors of under one horsepower and less than 460 volts, use:
1. electronically commutated motors (brushless direct current motors); or
2. 3‐phase motors;
(F) for condenser fan motors of under one horsepower, use:
1. electronically commutated motors;
2. permanent split capacitor‐type motors; or
3. 3‐phase motors; and
(G) for all interior lights, use light sources with an efficacy of 40 lumens per watt (LPW) or more, including ballast losses (if any), except that light sources with an efficacy of 40 LPW or less, including ballast losses (if any), may be used in conjunction with a timer or device that turns off the lights within 15 minutes of when the walk‐in cooler or walk‐in freezer is not occupied by people.
In addition to the design standards in Section 1605.1(a)(4)of this Article, walk‐in coolers equipped with transparent reach‐in doors and walk‐in freezers equipped with transparent reach‐in doors and manufactured on or after January 1, 2009 shall also meet the following design standards:
(A) Transparent reach‐in doors for walk‐in freezers and windows in walk‐in freezer doors shall be of triple‐pane glass with either heat‐reflective treated glass or gas fill;
(B) Transparent reach‐in doors for walk‐in coolers and windows in walk‐in cooler doors shall be either:
1. double‐pane glass with heat‐reflective treated glass and gas fill; or
2. triple‐pane glass with either heat‐reflective treated glass or gas fill;
(C) If the walk-in cooler or walk-in freezer has an anti-sweat heater
1. without anti-sweat heat controls, the walk in cooler or walk-in freezer shall have a total door rail, glass, and frame heater power draw of not more than 7.1 watts per square foot (W/ft2) of door opening (for freezers) and 3.0 watts per square foot (W/ft2) of door opening (for coolers);
2. with anti-sweat heat controls, and the total door rail, glass, and frame heater power draw is more than 7.1 watts per square foot (W/ft2) of door opening (for freezers) and 3.0 watts per square foot (W/ft2) of door opening (for coolers), the anti-sweat heat controls shall reduce the energy use of the anti-sweat heater in a quantity corresponding to the relative humidity in the air outside the door or to the condensation on the inner glass pane.
(D) Walk-in cooler and freezer display doors. All walk-in cooler and walk-in freezer display doors manufactured on or after June 5, 2017, must not exceed the standards shown in Table A-10:
Table A-10
Standards for Walk-in Cooler and Walk-in Freezer Display Doors
Manufactured On or After June 5, 2017
| Class Descriptor | Class | Maximum Daily Energy Consumption (kWh/day)* |
| Display Door, Medium Temperature | DD.M | 0.04 X Add + 0.41 |
| Display Door, Low Temperature | DD.L | 0.15 X Add + 0.29 |
| *Add represents the surface area of the display door. | ||
(E) Walk-in cooler and freezer non-display doors. All walk-in cooler and walk-in freezer non-display doors manufactured on or after June 5, 2017, must not exceed the standards shown in Table A-11:
Standards for Walk-in Cooler and Walk-in Freezer Non-Display Doors Manufactured On or After June 5, 2017
| Class Descriptor | Class | Maximum Daily Energy Consumption (kWh/day)* |
| Passage Door, Medium Temperature | PD.M | 0.05 X And + 1.7 |
| Passage Door, Low Temperature | PD.L | 0.14 X And+ 4.8 |
| Freight Door, Medium Temperature | FD.M | 0.04 X And + 1.9 |
| Freight Door, Low Temperature | FD.L | 0.12 X And + 5.6 |
| *And represents the surface area of the non-display door | ||
(F) Walk-in cooler and freezer refrigeration systems. The annual walk-in energy factor of all walk-in cooler and walk-in freezer refrigeration systems manufactured on or after January 1, 2020, must not be less than the values shown in Table A-12:
Standards for Walk-in Cooler and Walk-in Freezer Refrigeration Systems
Manufactured On or After January 1, 2020
| Class Descriptor | Class | Minimum AWEF (Btu/W-h |
| Dedicated Condensing, Medum Temperature, Indoor System | DC, M, I | 5.61 |
| Dedicated Condensing, Medum Temperature, Outdoor System | DC, M, 0 | 7.60 |
(A) Refrigerated Canned and Bottled Beverage Vending Machines Manufactured Before January 8, 2019. The daily energy consumption (in kilowatt hours per day) when measured at the 75°F ± 2°F and 45 ± 5% RH condition of each refrigerated bottled or canned beverage vending machine manufactured on or after the effective dates shown shall be not greater than the values shown in Table A-13:
Standards for Refrigerated Canned and Bottled Beverage Vending Machines
Manufactured On or After August 31, 2012 and Before January 8, 2019
| Equipment Class | Maximum Daily Energy Consumption (MDEC) (kWh) |
| Class A | 0.055 × V + 2.56 |
| Class B | 0.073 × V + 3.16 |
| Combination Vending Machines | RESERVED |
| V= Representative value of refrigerated volume in ft3 | |
(B) Refrigerated Canned and Bottled Beverage Vending Machines Manufactured On or After January 8, 2019. The daily energy consumption (in kilowatt hours per day) of refrigerated canned and bottled beverage vending machines manufactured on or after January 8, 2019 shall not exceed the values shown in Table A-14:
Standards for Refrigerated Canned and Bottled Beverage Vending Machines
Manufactured on or After January 8, 2019
| Equipment Class | Maximum Daily Energy Consumption (MDEC) (kWh) |
| Class A | 0.052 X V + 2.43 |
| Class B | 0.052 X V + 2.20 |
| Combination A | 0.086 X V + 2.66 |
| Combination B | 0.111 X V + 2.04 |
| V = Representative value of refrigerated volume in ft3 | |
(A) consumer refrigeration coolers manufactured before October 28, 2019; and
(B) water dispensers.
Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps Manufactured On or After June 1, 2014
| Appliance | Louvered Sides | Cooling Capacity (Btu/hr) | Minimum Combined EER |
| Room Air Conditioner | Yes | < 6,000 | 11.0 |
| Room Air Conditioner | Yes | ≥ 6,000 – ≤7,999 | 11.0 |
| Room Air Conditioner | Yes | ≥ 8,000 – ≤13,999 | 10.9 |
| Room Air Conditioner | Yes | ≥ 14,000 – ≤19,999 | 10.7 |
| Room Air Conditioner | Yes | ≥ 20,000 – ≤27,999 | 9.4 |
| Room Air Conditioner | Yes | ≥ 28,000 | 9.0 |
| Room Air Conditioner | No | < 6,000 | 10.0 |
| Room Air Conditioner | No | ≥ 6,000 – ≤7,999 | 10.0 |
| Room Air Conditioner | No | ≥ 8,000 – ≤10,999 | 9.6 |
| Room Air Conditioner | No | ≥ 11,000 – ≤13,999 | 9.5 |
| Room Air Conditioner | No | ≥ 14,000 – ≤9,999 | 9.3 |
| Room Air Conditioner | No | ≥20,000 | 9.4 |
| Room Air Conditioning Heat Pump | Yes | < 20,000 | 9.8 |
| Room Air Conditioning Heat Pump | Yes | ≥20,000 | 9.3 |
| Room Air Conditioning Heat Pump | No | < 14,000 | 9.3 |
| Room Air Conditioning Heat Pump | No | ≥14,000 | 8.7 |
| Casement‐Only Room Air Conditioner | Either | Any | 9.5 |
| Casement‐Slider Room Air Conditioner | Either | Any | 10.4 |
The EER and COP, as applicable, of non-standard size packaged terminal air conditioners and non standard size packaged terminal heat pumps manufactured on or after October 7, 2010, and of standard size packaged terminal air conditioners and standard size packaged terminal heat pumps manufactured on or after January 1, 2017 shall be not less than the applicable values shown in Tables B-3 and B-4.
Standards for Non-Standard Size Packaged Terminal Air Conditioners and Non-Standard Size Packaged Terminal Heat Pumps Manufactured On or after October 7, 2010
| Appliance | Cooling Capacity (Btu/hr) | Minimum Efficiency | |
|---|---|---|---|
| Minimum EER | Minimum COP | ||
| Packaged terminal air conditioners | < 7,000 | 9.4 | — |
| > 7,000 and < 15,000 | 10.9 – (0.213 x Cap1) | — | |
| > 15,000 | 7.7 | — | |
| Packaged terminal heat pumps | < 7,000 | 9.3 | 2.7 |
| > 7,000 and < 15,000 | 10.8 – (0.213 x Cap1) | 2.9 ‐ (0.026 x Cap1) | |
| > 15,000 | 7.6 | 2.5 | |
| 1Cap means cooling capacity in thousand British thermal units per hour (Btu/h) at 95°F outdoor dry-bulb | |||
Standards for Standard Size Packaged Terminal Air Conditioners and Standard Size Packaged Terminal Heat Pumps Manufactured On or after January 1, 2017
| Appliance | Cooling Capacity (Btu/hour) | Minimum Efficiency | |
|---|---|---|---|
| Minimum EER | Minimum COP | ||
| Packaged Terminal Air Conditioners | < 7,000 | 11.9 | |
| ≥ 7,000 < 15,000 | 14.0-(0.300 x Cap1) | ||
| ≥ 15,000 | 9.5 | ||
| Packaged Terminal Heat Pumps | < 7,000 | 11.9 | 3.3 |
| ≥ 7,000 < 15,000 | 14.0-(0.300 x Cap1) | 3.7 – (0.52 x Cap1) | |
| ≥ 15,000 | 9.5 | 2.9 | |
| 1 Cap means cooling capacity in thousand British thermal units per hour (Btu/h) at 95°F outdoor dry‐bulb temperature. | |||
Standards for Single Phase Air-Cooled Air Conditioners with Cooling Capacity
Less than 65,000 Btu per Hour and Single Phase Air-Source Heat Pumps with Cooling Capacity Less than 65,000 Btu per Hour, Not Subject to EPAct, Manufactured on or After January 1, 2015, but Before January 1, 2023
| hoihp;bn | ||||
| Product Class | Minimum SEER | Minimum HSPF | Minimum EER | Average Off‐ Mode Power Consumption Pw. pff (watts) |
| Split system air conditioners with rated cooling capacity < 45,000 Btu/hour¹ | 13.0 |
|
12.2 | 30 |
| Split system air conditioners with rated cooling capacity ≥ 45,000 Btu/hour¹ | 13.0 | 11.7 | 30 | |
| Split system heat pumps | 14.0 | 8.2 |
|
33 |
| Split system heat pumps with rated cooling capacity ≥ 45,000 Btu/hour¹ |
|
33 | ||
| Single package air conditioners1 | 14.0 |
|
11.0 | 30 |
| Single package heat pumps | 14.0 | 8.0 |
|
33 |
| Space constrained air conditioners | 12.0 |
|
— | 30 |
| Space constrained heat pumps | 12.0 | 7.4 | — | 33 |
| Small duct, high velocity ‘air conditioner systems | 12.0 | 7.2 | — | 30 |
| Small duct, high velocity heat pump systems | 12.0 | 7.2 | — | 30 |
| 1 Minimum SEER of 14.0 required for units installed on or after January 1, 2015, but before January 1, 2023, in the states of Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, South Carolina, Tennessee, Texas, or Virginia, or in the District of Columbia. | ||||
Standards for Air Conditioners and Heat Pumps That Are Consumer Products, Manufactured on or After January 1, 2023
| Product Class | Minimum SEER2 | Minimum HPSF2 | Minimum EER21 | Maximum Average Off-Mode Power Consumption Pw, pff (watts)2 |
| Split system air conditioners with certified cooling capacity < 45,000 Btu/hour | 13.4/14.3* |
|
11.7/9.8** | 30 |
| Split system air conditioners with certified cooling capacity ≥ 45,000 Btu/hour | 13.4/13.8* |
|
11.2/9.8*** | 30 |
| Split system heat pumps | 14.3 | 7.5 |
|
33 |
| Single package air conditioners | 13.4 |
|
10.6 | 30 |
| Single package heat pumps | 13.4 | 6.7 |
|
33 |
| Small duct, high velocity air conditioner systems | 12.0 | 6.1 |
|
30 |
| Small duct, high velocity heat pump systems | 12.0 | 6.1 |
|
30 |
| Space constrained air conditioners | 11.7 |
|
|
30 |
| Space constrained heat pumps | 11.9 | 6.3 |
|
33 |
|
¹ Minimum EER2 standards for units that are installed in the Southwest (Arizona, California, Nevada, or New Mexico). 2 Maximum Average Off-Mode Power Consumption standard applies to units manufactured on or after January 1, 2015. * The higher minimum SEER2 standard applies to units that are installed in the Southwest. See 10 C.F.R. section 430.32(c) for less stringent federal standards applicable to these units that are manufactured on or after January 1, 2023, and installed in states other than the Southwest. ** The 11.7 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2. *** The 11.2 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2. | ||||
EXCEPTION to Section 1605.1(c)(1) Table C-5 of this Article: The standards shown in Table
C-5 do not apply to single package vertical air conditioners and single package vertical heat pumps (see Table C-7), packaged terminal air conditioners and packaged terminal heat pumps (see Tables B-3 and B-4), computer room air conditioners (see Table C-8), variable refrigerant flow multi-split air conditioners and heat pumps (see Table C-9), and double-duct air-cooled commercial package air conditioning and heating equipment (see Table C-10).
Standards for Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled) Air Conditioners and Air-Source Heat Pumps Subject to EPAct
(Standards Effective January 1, 2010 do not apply to Single Package Vertical Air Conditioners)
| Equipment Type | Cooling Capacity | Sub-category | Heating Type* | Efficiency Levels | Compliance date: Equipment Manufactured starting on |
| Small Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled, 3-Phase, Split-System) | < 65,000 Btu/h | AC | ALL | SEER = 13.0 | June 16, 2008 |
| HP |
SEER = 14.0 HSPF = 8.2 |
January 1, 2017 | |||
| Small Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled, 3-Phase, Single-Package) | < 65,000 Btu/h | AC | ALL | SEER = 14.0 | January 1, 2017 |
| HP |
SEER = 14.0 HSPF = 8.0 |
January 1, 2017 | |||
| Small Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 65,000 Btu/h and < 135,000 Btu/h | AC | N-E | EER = 11.2 | January 1, 20101 |
| IEER = 12.9 | January 1, 20182 | ||||
| IEER = 14.8 | January 1, 2023 | ||||
| A-O |
EER = 11.0 |
January 1, 20101 | |||
| IEER = 12.7 | January 1, 20182 | ||||
| IEER = 14.6 | January 1, 2023 | ||||
| HP | E-N |
EER = 11.0 COP = 3.3 IEER = 12.9 COP = 3.3 IEER = 14.8 COP = 3.4 |
January 1, 20101 | ||
| January 1, 20182 | |||||
| January 1, 2023 | |||||
| A-O |
EER = 10.8 COP = 3.3 IEER = 12.0 COP = 3.3 IEER = 13.9 COP = 3.4 |
January 1, 20101 | |||
| January 1, 20182 | |||||
| January 1, 2023 |
Standards for Commercial Package Air Conditioning and Heating Equipment (Water-Cooled) Air Conditioners, Commercial Package Air Conditioning and Heating Equipment (Evaporatively Cooled) Air Conditioners, and Small Commercial Package Water-Source Heat Pumps
| Equipment Type | Cooling Capacity | Subcategory | Heating Type* | Efficiency Levels | Compliance date: Equipment manufactured starting on |
| Small Commercial Package Air Conditioning and Heating Equipment (Water-Cooled) | < 65,000 Btu/h | AC | All | EER = 12.1 | October 29, 2003 |
| N-EA-O |
EER = 12.1 EER = 11.9 | ||||
| ≥65,000 Btu/h and < 135,000 Btu/h | June 2, 2013 |
| Large Commercial Package Air-Conditioning and Heating Equipment (Water-Cooled) | ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | N-EA-O |
EER = 12.5 EER = 12.3 |
June 2, 2014 | |||
| Very Large Commercial Package Air-Conditioning and Heating Equipment (Water-Cooled) | ≥ 240,000 Btu/h and < 760,000 Btu/h | AC | N-EA-O |
EER = 11.9 EER = 11.7 |
June 1, 2014 | |||
| Small Commercial Package Air-Conditioning and Heating Equipment (Evaporatively-Cooled) | < 65,000 Btu/h | AC | All | EER = 12.1 | October 29, 2003 | |||
| ≥ 65,000 Btu/h and < 135,000 Btu/h | AC | N-EA-O |
EER = 12.1 EER = 11.9 |
June 1, 2013 | ||||
| Large Commercial Package Air-Conditioning and Heating Equipment (Evaporatively-Cooled) | ≥ 135,000 Btu/h and < 240,000 Btu/h | ACAC | N-EA-O |
EER = 12.0 EER = 11.8 |
June 1, 2014 | |||
| Very Large Commercial Package Air-Conditioning and Heating Equipment (Evaporatively-Cooled) | ≥ 240,000 Btu/h and < 760,000 Btu/h | ACAC | N-EA-O |
EER = 11.9 EER = 11.7 |
June 1, 2014 | |||
| Small Commercial Package Air Conditioning and Heating Equipment (Water-Source: Water-to-Air, Water-Loop) | < 17,000 Btu/h≥ 17,000 Btu/h and < 135,00 Btu/h | HP | All | EER = 12.2 | October 9, 2015 | |||
|
COP = 4.3 EER = 13.0 COP = 4.3 | ||||||||
|
1 And manufactured before January 1, 2018. 2 And manufactured before January 1, 2023. 3 COP standard remains in effect on and after January 1, 2023. * E-N = Electric Resistance Heating or No Heating A-O = All Other Types of Heating | ||||||||
Standards for Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps Manufactured on or After January 1, 2010
| Equipment Type | Cooling Capacity | Sub-category | Efficiency Levels | Compliance date: Products manufactured on and after |
| Single Package Vertical Air-Conditioners and Single Package Vertical Heat Pumps, single-phase and three-phase | < 65,000 Btu/h | AC | EER = 9.0 | January 1, 2010 |
| EER = 11.0 | September 23, 2019 | |||
| HP | EER = 9.0 COP = 3.0 | January 1, 2010 | ||
| EER = 11.0 COP = 3.3 | September 23, 2019 | |||
| Single Package Vertical Air-Conditioners and Single Package Vertical Heat Pumps | ≥ 65,000 Btu/h and < 135,000 Btu/h | AC | EER = 10.0 | October 9, 2015 |
| HP | EER = 10.0 COP = 3.0 | |||
| ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | EER = 10.0 | October 9, 2016 | |
| HP | EER = 10.0 COP = 3.0 |
Standards for Computer Room Air Conditioners
| Equipment type | Net sensible ‘cooling capacity (Btu/hr) | Minimum SCOP efficiency |
Compliance date: | |
| Downflow unit | Upflow unit | |||
| Air‐Cooled | <65,000 | 2.20 | 2.09 | October 29, 2012 |
| ≥65,000 and <240,000 | 2.10 | 1.99 | October 29, 2013 | |
| ≥240,000 and <760,000 | 1.90 | 1.79 | October 29, 2013 | |
| Water‐Cooled | <65,000 | 2.60 | 2.49 | October 29, 2012 |
| ≥65,000 and <240,000 | 2.50 | 2.39 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.40 | 2.29 | October 29, 2013 | |
| Water‐Cooled with a Fluid Economizer | <65,000 | 2.55 | 2.44 | October 29, 2012 |
| ≥65,000 and <240,000 | 2.45 | 2.34 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.35 | 2.24 | October 29, 2013 | |
| Glycol‐Cooled | <65,000 | 2.50 | 2.39 | October 29, 2012 |
| ≥65,000 and <240,000 | 2.15 | 2.04 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.10 | 1.99 | October 29, 2013 | |
| Glycol‐Cooled with a Fluid Economizer | <65,000 | 2.45 | 2.34 | October 29, 2012 |
| ≥65,000 and <240,000 | 2.10 | 1.99 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.05 | 1.94 | October 29, 2013 | |
| Equipment type | Cooling capacity (Btu/h) | Heating type1 | Efficiency level |
Compliance date: Products manufactured on and after… | |
| VRF Multi-Split Air Conditioners (Air-Cooled) | <65,000 | All | 13.0 SEER | June 16, 2008 | |
| ≥65,000 and < 135,000 | N-E | 11.2 EER | January 1, 2010 | ||
| A-O | 11.0 EER | January 1, 2010 | |||
| ≥135,000 and <240,000 | N-E | 11.0 EER | January 1, 2010 | ||
| A-O | 10.8 EER | January 1, 2010 | |||
| ≥240,000 and <760,000 | N-E | 10.0 EER | January 1, 2010 | ||
| A-O | 9.8 EER | January 1, 2010 | |||
| VRF Multi-Split Heat Pumps (Air-Cooled) | <65,000 | All |
13.0 SEER 7.7 HSPF |
June 16, 2008 | |
| ≥65,000 and < 135,000 | N-E |
11.0 EER 3.3 COP |
January 1, 2010 | ||
| A-O |
10.8 EER 3.3 COP |
January 1, 2010 | |||
| ≥135,000 and <240,000 | N-E |
10.6 EER 3.2 COP |
January 1, 2010 | ||
| A-O |
10.4 EER 3.2 COP |
January 1, 2010 | |||
| ≥240,000 Btu/h and <760,000 Btu/h | N-E |
9.5 EER 3.2 COP |
January 1, 2010 | ||
| A-O |
9.3 EER 3.3 COP |
January 1, 2010 | |||
| VRF Multi-Split Heat Pumps (Water Source) | <17,000 Btu/h | Without Heat Recovery |
12.0 EER 4.2 COP |
October 29, 2012 October 29, 2003 | |
| With Heat Recovery |
11.8 EER 4.2 COP |
October 29, 2012 October 29, 2003 | |||
| ≥17,000 Btu/h and <65,000 Btu/h | All |
12.0 EER 4.2 COP |
October 29, 2003 | ||
| ≥65,000 Btu/h and <135,000 Btu/h | All |
12.0 EER 4.2 COP |
October 29, 2003 | ||
| ≥135,000 Btu/h and <760,000 Btu/h | Without Heat Recovery |
10.0 EER 3.9 COP |
October 29, 2013 | ||
| With Heat Recovery |
9.8 EER 3.9 COP |
October 29, 2013 | |||
|
1VRF Multi-Split Heat Pumps ( Air-Cooled ) with heat recovery fall under the category of “All Other Types of Heating” unless they also have electric resistance heating, in which case it falls under the category for “No Heating or Electric Resistance Heating.” *N-E = No Heating or Electric resistance heating A-O = All Other Types of Heating | |||||
| Equipment Type | Cooling Capacity | Sub-category | Heating Type* | Efficiency Levels |
| Small Double-Duct Commercial Packaged Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 65,000 Btu/h and < 135,000 Btu/h | AC | E-N | EER = 11.2 |
| A-O | EER = 11.0 | |||
| HP | E-N |
EER = 11.0 COP = 3.3 | ||
| A-O |
EER = 10.8 COP = 3.3 | |||
| Large Commercial Double-Duct Packaged Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | E-N | EER = 11.0 |
| A-O | EER = 10.8 | |||
| HP | E-N |
EER = 10.6 COP = 3.2 | ||
| A-O |
EER = 10.4 COP = 3.2 | |||
| Very Large Double-Duct Commercial Packaged Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 240,000 Btu/h and < 300,000 Btu/h | AC | E-N | EER = 10.0 |
| A-O | EER = 9.8 | |||
| HP | E-N |
EER = 9.5 COP = 3.2 | ||
| A-O |
EER = 9.3 COP = 3.2 | |||
|
* E-N = No Heating or Electric Resistance Heating A-O = All Other Types of Heating 1For units tested using the relevant AHRI Standards, all COP values must be rated at 47◦F outdoor dry-bulb temperature for air-cooled equipment. | ||||
Standards for Direct Expansion-Dedicated Outdoor Air Systems Manufactured on or After May 1, 2024
| Subcategory | Minimum Efficiency Level |
| (AC) -- Air-cooled without ventilation energy recovery systems | ISMRE2 = 3.8 |
| (AC w/VERS) -- Air-cooled with ventilation energy recovery systems | ISMRE2 = 5.0 |
| (ASHP) -- Air-source heat pumps without ventilation energy recovery systems | ISMRE2 = 3.8 ISCOP2 = 2.05 |
|
|
|
| (ASHP w/VERS) -- Air-source heat pumps with ventilation energy recovery systems | ISMRE2 = 5.0 ISCOP2 = 3.20 |
|
|
|
| (WC) -- Water-cooled without ventilation energy recovery systems | ISMRE2 = 4.7 |
| (WC w/VERS) -- Water-cooled with ventilation energy recovery systems | ISMRE2 = 5.1 |
| (WSHP) -- Water-source heat pumps without ventilation energy recovery systems | ISMRE2 = 3.8 ISCOP2 = 2.13 |
|
|
|
| (WSHP w/VERS) -- Water-source heat pumps with ventilation energy recovery systems | ISMRE2 = 4.6 ISCOP2 = 4.04 |
Standards for Ceiling Fans Manufactured On or After January 21, 2020
| Ceiling Fan Type | Minimum Efficiency (CFM/Watts)1 |
| Very small-diameter (VSD) |
D ≤ 12 inches: 21 D >12 inches: 3.16D – 17.04 |
| Standard | 0.65 D + 38.03 |
| Hugger | 0.29 D + 34.46 |
| High-speed small-diameter (HSSD) | 4.16 D + 0.02 |
| 1D is the ceiling fan’s blade span, in inches. | |
(C) Large-Diameter Ceiling Fans. Large-diameter ceiling fans manufactured on or after January 21, 2020, shall have a CFEI greater than or equal to:
Requirements for CFLs Used in Ceiling Fan Light Kits with Medium Screw Base Sockets
| Factor | Requirements |
| Rated Wattage (Watts) & Configuration1 | Minimum Initial Lamp Efficacy (lumens per Watt)2 |
| Bare Lamp | |
| Lamp Power < 15 | 45.0 |
| Lamp Power ≥ 15 | 60.0 |
| Covered Lamp (no reflector): | |
| Lamp Power < 15 | 40.0 |
| 15 ≤ Lamp Power < 19 | 48.0 |
| 19 ≤ Lamp Power < 25 | 50.0 |
| Lamp Power ≥ 25 | 55.0 |
| With Reflector: | |
| Lamp Power < 20 | 33.0 |
| Lamp Power ≥ 20 | 40.0 |
| Lumen Maintenance at 1,000 hours | ≥ 90.0% |
| Lumen Maintenance at 40 percent of Lifetime | ≥ 80.0% |
| Rapid Cycle Stress Test | Each lamp must be cycled once for every 2 hours of lifetime. At least 5 lamps must meet or exceed the minimum number of cycles |
| Lifetime | ≥ 6,000 hours for the sample of lamps. |
|
1Use rated wattage to determine the appropriate minimum efficacy requirements in this table. 2Calculate efficacy using measured wattage, rather than rated wattage, and measured lumens to determine product compliance. Wattage and lumen values indicated on products or packaging may not be used in calculation. | |
System Efficacy Per Lamp Ballast Platform in Lumens Per Watt (lm/W)
| Lamp Description | Minimum Lumens Per Watt (lm/W) |
| All lamps below 30 total listed lamp watts | 50 lm/w |
| All lamps that are ≤ 24 inches and ≥ 30 total listed lamp watts. | 60 lm/w |
| All lamps that are > 24 inches and ≥ 30 total listed lamp watts. | 70 lm/w |
Standards for Ceiling Fan Light Kits Manufactured On or After January 21, 2020
| Lumens1 | Minimum required efficacy (lm/W) |
| < 120 | 50 |
| ≥ 120 | (74.0-29.42 x 0.9983lumens) |
| 1Use the lumen output for each basic model of lamp packaged with the basic model of ceiling fan light kit (CFLK) or each basic model of integrated SSL in the CFLK basic model to determine the applicable standard. | |
Standards for Ceiling Fan Light Kits with Medium Screw Base Sockets
Manufactured On or After January 21, 2020
| Criteria | Requirement |
| Lumen Maintenance at 1,000 Hours | ≥ 90% |
| Lumen Maintenance at 40% of Lifetime | ≥ 80% |
| Rapid Cycle Stress Test | Each lamp must be cycled once for every 2 hours of lifetime of compact fluorescent lamp. At least 5 Lamps must meet or exceed the minimum number of cycles. |
| Lifetime | ≥ 6,000 hours for the sample of lamps |
(3) Dehumidifiers.
Standards for Dehumidifiers Manufactured
On or After October 1, 2012 And Before June 13, 2019
| Product capacity (pint/day) | Minimum energy factor (liters/kWh) |
| Effective October 1, 2012 | |
| 25.00 or less | 1.35 |
| 25.01 – 35.00 | 1.35 |
| 35.01 – 45.00 | 1.50 |
| 45.01 – 54.00 | 1.60 |
| 54.01 – 74.99 | 1.70 |
| 75.00 or more | 2.50 |
Standards for Dehumidifiers Manufactured On or After June 13, 2019
| Portable dehumidifier product capacity (pints/day) | Minimum Integrated Energy Factor (liters/kWh) |
| 25.00 or less | 1.30 |
| 25.01 – 50.00 | 1.6 |
| 50.01 or more | 2.80 |
| Whole-home dehumidifier product case volume (ft3) | |
| 8.0 or less | 1.77 |
| More than 8.0 | 2.41 |
Energy Conservation Standards for Federally Covered Residential Furnace Fans
| Product Class | FER1 (Watts/1000cfm) |
| Non-Weatherized, Non-Condensing Gas Furnace Fan (NWG-NC) | FER = 0.044 x QMax + 182 |
| Non-Weatherized, Condensing Gas Furnace Fan (NWG-C) | FER = 0.044 x QMax + 195 |
| Weatherized, Non-Condensing Gas Furnace Fan (WG-NC) | FER = 0.044 x QMax + 199 |
| Non-Weatherized, Non-Condensing Oil Furnace Fan (NWO-NC) | FER = 0.071 x QMax + 382 |
| Non-Weatherized, Electric Furnace/Modular Blower Fan (NWEF/NWMB) | FER = 0.044 x QMax + 165 |
| Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC) | FER = 0.071 x QMax + 222 |
| Mobile Home Non-Weatherized, Condensing Gas Furnace Fan (MH-NWG-C) | FER = 0.071 x QMax + 240 |
| Mobile Home Electric Furnace/Modular Blower Fan (MH-EF/MB) | FER = 0.044 x QMax + 101 |
| Mobile Home Non-Weatherized, Oil Furnace Fan (mh-nwo) | Reserved |
| Mobile Home Weatherized, Gas Furnace Fan (MH-WG)** | Reserved |
|
1QMax is the airflow, in cfm, at the maximum airflow-control setting measured using the final DOE teat procedure at 10 CFR part 430, subpart B, appendix AA | |
Standards for Gas Vented Home Heating Equipment Manufactured on or After April 16, 2013
| Product Class |
Design Type |
Capacity (Btu per hour) |
Minimum AFUE (%) |
| Wall | Fan | ≤ 42,000 | 75 |
| Wall | Fan | > 42,000 | 76 |
| Wall | Gravity | ≤ 27,000 | 65 |
| Wall | Gravity | > 27,000 and ≤ 46,000 | 66 |
| Wall | Gravity | > 46,000 | 67 |
| Floor | All | ≤ 37,000 | 57 |
| Floor | All | > 37,000 | 58 |
| Room | All | ≤ 20,000 | 61 |
| Room | All | > 20,000 and ≤ 27,000 | 66 |
| Room | All | > 27,000 and ≤ 46,000 | 67 |
| Room | All | > 46,000 | 68 |
Standards for Residential Boilers < 300,000 Btu/hour Input and Electric Residential Boilers
| Appliance | Minimum AFUE (%) | Maximum Power Consumption | ||||
|
Effective September 1, 2012 |
Effective January 15, 2021 | |||||
| AFUE | Standby | Off Mode | ||||
| Gas steam boilers with single phase electrical supply | 801 | 821 | 8 | 8 | ||
| Gas hot water boilers with single phase electrical supply | 821, 2 | 841, 2 | 9 | 9 | ||
| Oil steam boilers with single phase electrical supply | 82 | 85 | 11 | 11 | ||
| Oil hot water boilers with single phase electrical supply | 842 | 862 | 11 | 11 | ||
| Electric steam residential boilers | NONE | NONE | 8 | 8 | ||
| Electric hot water residential boilers | NONE2 | NONE2 | 8 | 8 | ||
|
¹ No constant burning pilot light design standard effective September 1, 2012. ² Automatic means for adjusting temperature design standard effective September 1, 2012. (Boilers equipped with tankless domestic water heating coils do not need to comply with this requirement.) | ||||||
Standards for Gas- and Oil-Fired Commercial Packaged Boilers ≥ 300,000 Btu/hour Input
| Appliance | Type | Rated Input (Btu/hr) | Minimum Efficiency (%) | ||
| Combustion Efficiency % | Thermal Efficiency % | ||||
| March 2, 2012 |
March 2, 2012 through March 1, 2022 |
March 2, 2022 | |||
| Hot Water Boilers | Gas‐fired | ≥ 300,000 and ≤2,500,000 |
|
80 | 80 |
| > 2,500,000 | 82 | — | — | ||
| Oil‐fired | ≥ 300,000 and ≤2,500,000 |
|
82 | 82 | |
| > 2,500,000 | 84 | — | — | ||
| Steam Boilers | Gas‐fired, except natural draft | ≥ 300,000 and ≤2,500,000 |
|
79 | 79 |
| > 2,500,000 | |||||
| Gas‐fired, natural draft | ≥ 300,000 and ≤2,500,000 |
|
77 | 79 | |
| > 2,500,000 | |||||
| Oil‐fired | ≥ 300,000 and ≤2,500,000 |
|
81 | 81 | |
| > 2,500,000 | |||||
Standards for Commercial Central Warm Air Furnaces
| Appliance | Rated Input (Btu/hr) | Minimum Thermal Efficiency | |
| January 1, 1994 | January 1, 2023 | ||
| Gas central warm air furnaces | ≥ 225,000 | 80 | 81 |
| Oil central warm air furnaces | ≥ 225,000 | 81 | 82 |
Standards for Residential Central Furnaces
| Product class | AFUE (percent) | Maximum Electrical Power Consumption | |
| Standby | Off Mode | ||
| (A) Non-weatherized gas furnaces (not including mobile home furnaces) | 80 | No requirement | |
| (B) Mobile Home gas furnaces | 80 | No requirement | |
| (C) Non-weatherized oil-fired furnaces (not including mobile home furnaces) | 83 | 11 | 11 |
| (D) Mobile Home oil-fired furnaces | 75 | 11 | 11 |
| (E) Weatherized gas furnaces | 81 | No requirement | |
| (F) Weatherized oil-fired furnaces | 78 | No requirement | |
| (G) Electrical furnaces | 78 | 10 | 10 |
Standards for Water Heaters Regulated Under 10 C.F.R. Section 430.32(d)
| Product Class | Rated Storage Volume and Input Rating (if applicable) | Draw Pattern | Minimum Uniform Energy Factor* |
| Gas-Fired Storage Water Heater | ≥ 20 gallons and ≤ 55 gallons | Very small | 0.3456 – (0.0020 x Vr) |
| Low | 0.5982 – (0.0019 x Vr) | ||
| Medium | 0.6483 – (0.0017 x Vr) | ||
| High | 0.6920 – (0.0013 x Vr) | ||
| > 55 gallons and ≤ 100 gallons | Very small | 0.6470 – (0.0006 x Vr) | |
| Low | 0.7689 – (0.0005 x Vr) | ||
| Medium | 0.7897 – (0.0004 x Vr) | ||
| High | 0.8072 – (0.0003 x Vr) | ||
| Oil-Fired Storage Water Heater | ≤ 50 gallons | Very small | 0.2509 – (0.0012 x Vr) |
| Low | 0.5330 – (0.0016 x Vr) | ||
| Medium | 0.6078 – (0.0016 x Vr) | ||
| High | 0.6815 – (0.0014 x Vr) | ||
| Electric Storage Water Heaters | ≥ 20 gallons and ≤ 55 gallons | Very small | 0.8808 – (0.0008 x Vr) |
| Low | 0.9254 – (0.0003 x Vr) | ||
| Medium | 0.9307 – (0.0002 x Vr) | ||
| High | 0.9349 – (0.0001 x Vr) | ||
| > 55 gallons and ≤ 120 gallons | Very small | 1.9236 – (0.0011 x Vr) | |
| Low | 2.0440 – (0.0011 x Vr) | ||
| Medium | 2.1171 – (0.0011 x Vr) | ||
| High | 2.2418 – (0.0011 x Vr) | ||
| Tabletop Water Heater | ≥ 20 gallons and ≤ 120 gallons | Very small | 0.6323 – (0.0058 x Vr) |
| Low | 0.9188 – (0.0031 x Vr) | ||
| Medium | 0.9577 – (0.0023 x Vr) | ||
| High | 0.9884 – (0.0016 x Vr) | ||
| Instantaneous Gas-fired Water Heater | < 2 gallons and > 50,000 Btu/h | Very small | 0.80 |
| Low | 0.81 | ||
| Medium | 0.81 | ||
| High | 0.81 | ||
| Instantaneous Electric Water Heater | < 2 gallons | Very small | 0.91 |
| Low | 0.91 | ||
| Medium | 0.91 | ||
| High | 0.92 | ||
| Grid-Enabled Water Heater | > 75 gallons | Very small | 1.0136 – (0.0028 x Vr) |
| Low | 0.9984 – (0.0014 x Vr) | ||
| Medium | 0.9853 – (0.0010 x Vr) | ||
| High | 0.9720 – (0.0007 x Vr) | ||
|
*Vr = Rated Storage Volume in gallons | |||
Standards for Water Heaters Regulated Under 42 U.S.C. section 6295(e)(1)
| Product Class | Minimum Energy Factor* |
| Gas Water Heater1 | 0.62 – (0.0019 x Vr) |
| Oil Water Heater1 | 0.59 – (0.0019 x Vr) |
| Electric Water Heater1 | 0.95 – (0.00132 x Vr) |
|
*Vr = Rated Storage Volume in gallons 1Applies to water heaters not covered under 10 C. F.R. section 430.32, including but not limited to storage water heaters >1 gal and < 20 gal (mini-tank water heaters) and booster water heaters. These standards will take effect on the effective date of a federal test procedure that converts Uniform Energy Factor (UEF) to Energy Factor for these products. If the Secretary adopts federal efficiency standards for water heaters regulated under 42 U. S. C. section 6295(e)(1), these standards shall not apply | |
Standards for Water Heaters Regulated Under 10 C.F.R. Section 431.110(a)
(Excluding Residential-Duty Commercial Water Heaters)
| Equipment Category | Size | Energy Conservation Standardsa | |
| Maximum standby lossc (equipment manufactured on and after October 29, 2003)b | Minimum thermal efficiency (equipment manufactured on and after October 9, 2015)b (%) | ||
| Electric storage water heaters | All | 0.30 + 27/Vm (%/hr) | N/A |
| Gas-fired storage water heaters | ≤ 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 |
| > 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | |
| Oil-fired storage water heaters | ≤ 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 |
| > 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | |
| Gas-fired instantaneous water heaters and hot water supply boilers | < 10 gallons | N/A | 80 |
| ≥ 10 gallons | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | |
| Oil-fired instantaneous water heaters and hot water supply boilers | < 10 gallons | N/A | 80 |
| ≥ 10 gallons | Q/800 + 110(Vr) ½ (Btu/hr) | 78 | |
|
aVm is the measured storage volume (in gallons), and Vr is the rated volume (in gallons). Q is the nameplate input rate in Btu/hr. bFor hot water supply boilers with a capacity of less than 10 gallons: (1) The standards are mandatory for products manufactured on and after October 21, 2005; and (2) products manufactured prior to that date, and on or after October 23, 2003, must meet either the standards listed in Table F-4 or the applicable standards in section 1605.1(e) of this Article for a “commercial packaged boiler.” cWater heaters and hot water supply boilers having more than 140 gallons of storage capacity need not meet the standby loss requirement if: (1) The tank surface area is thermally insulated to R-12.5 or more (2) a standing pilot light is not used; and (3) for gas or oil-fired storage water heaters, they have a fire damper or fan-assisted combustion. | |||
Standards for Residential-Duty Commercial Water Heaters
| Product Class | Specifications | Draw Pattern | Minimum Uniform Energy Factor* |
| Gas-Fired Storage |
>75 kBtu/hr and ≤ 105 kBtu/hr and ≤ 120 gallons |
Very Small | 0.2674 – (0.0009 x Vr) |
| Low | 0.5362 – (0.0012 x Vr) | ||
| Medium | 0.6002 – (0.0011 x Vr) | ||
| High | 0.6597 – (0.09 x Vr) | ||
| Oil-Fired Storage | > 105 kBtu/hr and≤ 140 kBtu/hr and≤ 120 gallons | Very Small | 0.2932 – (0.0015 x Vr) |
| Low | 0.5596 – (0.0018 x Vr) | ||
| Medium | 0.6194 – (0.0016 x Vr) | ||
| High | 0.6740 – (0.0013 x Vr) | ||
| Electric Instantaneous | >12 kW and≤ 58.6 kW and≤ 2 gallons | Very small | 0.80 |
| Low | 0.80 | ||
| Medium | 0.80 | ||
| High | 0.80 | ||
|
aAdditionally, to be classified as a residential-duty commercial water heater, a commercial water heater must meet the following conditions: (1) if the water heater requires electricity, it must use a single-phase external power supply; and (2) the water heater must not be designed to heat water to temperatures greater than 180F. bVr is the rated storage volume (in gallons), as determined pursuant to 10 CFR section 429.44 | |||
Standards for Fossil Fuel-Fired Pool Heaters
| Appliance | Effective Date | Minimum Thermal Efficiency (%) |
| Gas-Fired Pool Heaters | April 16, 2013 | 82 |
| Oil-Fired Pool Heaters | January 1, 1990 | 78 |
(A) For the purposes of section 1605.1(g)(6)(B) of this Article, “PEICL” means the constant load pump energy index and “PEIvL” means the variable load pump energy index, both as determined in accordance with the test procedure in section 1604(g)(3)(A) of this Article. For the purposes of section 1605.1(g)(6)(D) of this Article, “BEP” means the best efficiency point as determined in accordance with the test procedure in section section 1604(g)(3)(A) of this Article.
Standards for Pumps Manufactured On or After January 27, 2020
| Equipment Class1 | Maximum PEI2 | C-value3 |
| ESCC.1800.CL | 1.00 | 128.47 |
| ESCC.3600.CL | 1.00 | 130.42 |
| ESCC.1800.VL | 1.00 | 128.47 |
| ESCC.3600.VL | 1.00 | 130.42 |
| ESFM.1800.CL | 1.00 | 128.85 |
| ESFM.3600.CL | 1.00 | 130.99 |
| ESFM.1800.VL | 1.00 | 128.85 |
| ESFM.3600.VL | 1.00 | 130.99 |
| IL.1800.CL | 1.00 | 129.30 |
| IL.3600.CL | 1.00 | 133.84 |
| IL.1800.VL | 1.00 | 129.30 |
| IL.3600.VL | 1.00 | 133.84 |
| RSV.1800.CL | 1.00 | 129.63 |
| RSV.3600.CL | 1.00 | 133.20 |
| RSV.1800.VL | 1.00 | 129.63 |
| RSV.3600.VL | 1.00 | 133.20 |
| ST.1800.CL | 1.00 | 138.78 |
| ST.3600.CL | 1.00 | 134.85 |
| ST.1800.VL | 1.00 | 138.78 |
| ST.3600.VL | 1.00 | 134.85 |
|
1Equipment class designations consist of a combination (in sequential order separated by periods) of: (1) An equipment family (ESCC = end suction close-coupled, ESFM – end suction frame mounted/own bearing, IL = in-line, RSV = radially split, multi-stage, vertical, in-line diffuser casing, ST = submersible turbine; all as defined in 10 C.F.R. section 431.462); (2) nominal speed of rotation (1800 = 1800 rpm, 3600 = 3600 rpm); and (3) an operating mode (CL = constant load, VL = variable load). Determination of the operating mode is determined using the test procedure in appendix A to this subpart. 2For equipment classes ending in .CL, the relevant PEI is PEICL. For equipment classes ending in .VL, the relevant PEI is PEIVL. 3The C-values shown in this table must be used in the equation for PERSTD when calculating PEICL or PEIVL, as described in section II.B of 10 C.F.R. Appendix A to subpart Y of part 431. | ||
a. a 2- or 4-pole induction motor; or
b. a non-induction motor with a speed of rotation operating range that includes speeds of rotation between 2,880 and 4,320 revolutions per minute and/or 1,440 and 2,160 revolutions per minute; and
c. in either case, the driver and impeller must rotate at the same speed;
Table G-3: Standards for Dedicated-Purpose Pool Pumps Manufactured on or After July 19, 2021
| Equipment Class |
|
|
Minimum allowable WEF score [kgal/kWh] |
| Dedicated-purpose pool pump variety | hhp Applicability | Motor phase |
|
|
| |||
| Self-priming pool filter pumps | 0.711 hp ≤ hhp < 2.5 hp | Single | WEF = 2.30 * ln (hhp) + 6.59. |
|
| |||
| Self-priming pool filter pumps | hhp <0.711 hp | Single | WEF = 5.55, for hhp ≤ 0.13 hp -1.30 * ln (hhp)+ 2.90, for hhp >0.13 hp. |
|
| |||
| Non-self-priming pool filter pumps | hhp <2.5 hp | Any | WEF = 4.60, for hhp ≤ 0.13 hp -0.85 * ln (hhp) + 2.87, for hhp >0.13 hp. |
| Pressure cleaner booster pumps | Any | Any | WEF = 0.42. |
Standards for Plumbing Fittings
| Appliance | Maximum Flow Rate |
| Wash fountains | 2.2 x rim space (inches)/20 gpm at 60psi |
| Metering faucets | 0.25 gallons/cycle 1, 2 |
| Metering faucets for wash fountains | 0.25xrim space (inches)/20 gpm at 60 psi 1, 2 |
|
1Sprayheads with independently‐controlled orifices and manual controls. The maximum flow rate of each orifice that delivers a pre‐set volume of water before gradually shutting itself off shall not exceed the maximum flow rate for a metering faucet. 2Sprayheads with collectively‐controlled orifices and metered controls. The maximum flow rate of a sprayhead that delivers a pre‐set volume of water before gradually shutting itself off shall be the product of (a) the maximum flow rate for a metering ‘faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)). | |
Standards for Commercial Pre-rinse Spray Valves Manufactured On or After January 28, 2019
| Product Class (spray force in ounce force (ozf) | Maximum Flow Rate (gpm) |
| Product Class 1 ( ≤ 5.0 ozf) | 1.00 |
| Product Class 2 ( > 5.0 ozf and ≤ 8.0 ozf) | 1.20 |
| Product Class 3 ( > 8.0 ozf ) | 1.28 |
See Section 1605.3(i) of this Article for water efficiency standards for plumbing fixtures.
Standards for Fluorescent Lamp Ballasts, Except for Certain Dimming Ballasts
Applicable to Models Described in Section 1605.1(j)(1) of this Article
| BLE = A/(1 +B*average total lamp arc power ᴧ -C) Where A, B, and C are as follows: | |||
| Description | A | B | C |
| Instant start and rapid start ballasts (not classified as residential) that are designed to operate | 0.993 | 0.27 | 0.25 |
| 4‐foot medium bipin lamps |
|
|
|
| 2‐foot U‐shaped lamps |
|
|
|
| 8-foot slimline lamps |
|
|
|
| Programmed start ballasts (not classified as residential) that are designed to operate | 0.993 | 0.51 | 0.37 |
| 4‐foot medium bipin lamps |
|
|
|
| 2‐foot U‐shaped lamps |
|
|
|
| 4‐foot miniature bipin standard output lamps |
|
|
|
| 4‐foot miniature bipin high output lamps |
|
|
|
| Instant start and rapid start ballasts (not classified as sign ballasts) that are designed to operate 8-foot high output lamps | 0.993 | 0.38 | 0.25 |
| Programmed start ballasts (not classified as sign ballasts) that are designed to operate 8-foot high output lamps | 0.973 | 0.70 | 0.37 |
| Sign ballasts that operate 8-foot high output lamps | 0.993 | 0.47 | 0.25 |
| Instant start and rapid start residential ballasts that operate | 0.993 | 0.41 | 0.25 |
| 4‐foot medium bi‐pin lamps |
|
|
|
| 2‐foot U‐shaped lamps |
|
|
|
| 8-foot slimline lamps |
|
|
|
| Programmed start residential ballasts that are designed to operate | 0.973 | 0.71 | 0.37 |
| 4‐foot medium bi‐pin lamps |
|
|
|
| 2‐foot U‐shaped lamps |
|
|
|
Standards for Certain Dimming Fluorescent Lamp Ballasts, Ballast Luminous Efficiency Applicable to Models Described in section 1605.1(j)(1) of this Article
| Designed for the Operation of | Ballast Input Voltage | Total Nominal Lamp Watts | Ballast Luminous Efficiency | |
| Low Frequency Ballasts | High Frequency Ballasts | |||
| One F34T12 lamp | 120 / 277 | 34 | 0.777 | 0.778 |
| Two F34T12 lamps | 120 / 277 | 68 | 0.804 | 0.805 |
| Two F96T12/ES lamps | 120 / 277 | 120 | 0.876 | 0.884 |
| Two F96T12HO/ES lamps | 120 / 277 | 190 | 0.711 | 0.713 |
Each of the following federally regulated general service fluorescent lamps manufactured on or after the effective dates shown shall meet or exceed the lamp efficacy standards shown in Table K-2
Standards for Federally-Regulated General Service Fluorescent Lamps
Manufactured On or After July 15, 2012
| Appliance | Correlated Color Temperature | Minimum Average Lamp Efficacy (LPW) | |
|
Effective July 15, 2012 |
Effective January 26, 2018 | ||
| 4‐foot medium bipin lamps | ≤ 4,500K | 89 | 92.4 |
| > 4,500K and ≤ 7,000K | 88 | 88.7 | |
| 2‐foot U‐shaped lamps | ≤ 4,500K | 84 | 85.0 |
| > 4,500K and ≤ 7,000K | 81 | 83.3 | |
| 8-foot slimline lamps | ≤ 4,500K | 97 | 97.0 |
| > 4,500K and ≤ 7,000K | 93 | 93.0 | |
| 8‐foot high output lamps | ≤ 4,500K | 92 | 92.0 |
| > 4,500K and ≤ 7,000K | 88 | 88.0 | |
| 4-foot miniature bipin standard output | ≤ 4,500K | 86 | 95.0 |
| > 4,500K and ≤ 7,000K | 81 | 89.3 | |
| 4-foot miniature bipin high output | ≤ 4,500K | 76 | 82.7 |
| > 4,500K and ≤ 7,000K | 72 | 76.9 | |
Standards for Traffic Signals for Vehicle and Pedestrian Control
| Appliance | Maximum Wattage (at 74°C) | Nominal Wattage (at 25°C) |
| Traffic Signal Module Type: | ||
| 12‐inch; Red Ball | 17 | 11 |
| 8‐inch; Red Ball | 13 | 8 |
| 12‐inch; Red Arrow | 12 | 9 |
| 12‐inch; Green Ball | 15 | 15 |
| 8‐inch; Green Ball | 12 | 12 |
| 12‐inch; Green Arrow | 11 | 11 |
| Pedestrian Module Type: | ||
| Combination Walking Man/Hand | 16 | 13 |
| Walking Man | 12 | 9 |
| Orange Hand | 16 | 13 |
Standards for Metal Halide Lamp Fixtures Manufactured On or After February 10, 2017
| Designed to be operated with lamps of the following rated lamp wattage | Tested input voltage‡‡ | Minimum standard equation‡‡% |
| ≥ 50W and ≤ 100W | Tested at 480 V | (1/(1+1.24xP^(-0.351)))-0.020†; |
| ≥ 50W and ≤ 100W | All others | 1/(1+1.24xP^(-0.351)) |
| > 100W and < 150†;W | Tested at 480 V | (1/(1+1.24xP^(-0.351)))-0.020†; |
| > 100W and < 150†;W | All others | 1/(1+1.24xP^(-0.351)) |
| > 500W and ≤ 1000W | Tested at 480 V | For >500W and ≤ 750W: 0.900 |
| For >750W and ≤ 1000W: 0.000104xP+0.822 | ||
| For >500W and ≤ 1000W: may not utilize a probe-start ballast | ||
| > 500W and ≤ 1000W | All others | For >500W and ≤ 750W: 0.910 |
| For >750W and ≤ 1000W: 0.000104xP+0.832 | ||
| For >500W and ≤ 1000W: may not utilize a probe-start ballast | ||
|
† Includes 150 W fixtures specified in 10 C.F.R. section 431.326 paragraph (b)(3), that are fixtures rated only for 150 W lamps; rated for use in wet locations, as specified by the NFPA 70 section 410.4(A); and containing a ballast that is rated to operate at ambient air temperatures above 500 C †† P is defined as the rated wattage of the lamp the fixture is designed to operate. ‡‡ Tested input voltage is specified in 10 C.F.R section 431.324. | ||
EXCEPTION to Sections 1605.1(n)(2)(B) and 1605.1(n)(2)(C). of this Article, The standards described in sections 1605.1(n)(2)(B) and 1605.1(n)(2)(C) of this Article do not apply to metal halide lamp fixtures:
The maximum energy use and maximum water use of dishwashers that are consumer products manufactured on or after the effective dates shown shall meet the applicable values shown in Table O.
Table O
Standards for Dishwashers
| Appliance | Effective May 30, 2013 | |
| Maximum Energy Use (kWh/year) | Maximum Water Use (gallons/cycle) | |
| Compact dishwashers | 222 | 3.5 |
| Standard dishwashers | 307 | 5.0 |
Standards for Residential Clothes Washers Manufactured On or After January 1, 2018, but Before March 1, 2028
| Appliance | Minimum Integrated Modified Energy Factor |
Maximum Integrated Water Factor |
| January 1, 2018 | January 1, 2018 | |
| Top‐loading, Compact | 1.15 | 12.0 |
| Top‐loading, Standard | 1.57 | 6.5 |
| Front‐loading, Compact | 1.13 | 8.3 |
| Front‐loading, Standard | 1.84 | 4.7 |
Standards for Residential Clothes Washers Manufactured On or After March 1, 2028
Standards for Vented Electric Clothes Dryers, Ventless Electric Clothes Dryers, and Vented Gas Clothes Dryers Manufactured On or After January 1, 2015
| Appliance | Minimum Combined Energy Factor (lbs/kWh) | |
| Vented | Ventless | |
| Electric, standard clothes dryers | 3.73 | --- |
| Electric, compact, 120 volt clothes dryers | 3.61 | --- |
| Electric, compact, 240 volt clothes dryers | 3.27 | 2.55 |
| Electric, combination washer-dryer | --- | 2.08 |
| Gas clothes dryers | 3.3 | --- |
Microwave-only ovens, countertop convection microwave ovens, built-in microwave ovens, and over-the-range convection microwave ovens manufactured on or after the effective dates shown shall not exceed the average standby power rating (watts) shown in Table R-2 and R-3.
Table R-2-Standards for Microwave Ovens Manufactured On or After June 17, 2016
| Appliance | Maximum Standby Power (Watts) |
| Microwave-only oven | 1.0 |
| Countertop convection microwave oven | 1.0 |
| Built-in microwave oven | 2.2 |
| Over‐the‐range convection microwave oven | 2.2 |
Appliance | Maximum Standby Power (Watts) |
Microwave-only oven | 0.6 |
Countertop convection microwave oven | 0.6 |
Built-in microwave oven | 1.0 |
Over-the-range convection microwave oven | 1.0 |
Minimum Nominal Full-Load Efficiencies of NEMA Design A, NEMA Design B and
IEC Design N Motors (Excluding Fire Pump Electric Motors) at 60 Hz
| Motor Horsepower/ Standard kilowatt equivalent | Nominal Full‐Load Efficiency (%) | |||||||
| 2 pole | 4 pole | 6 pole | 8 pole | |||||
| Enclosed | Open | Enclosed | Open | Enclosed | Open | Enclosed | Open | |
| 1/.75 | 77.0 | 77.0 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 |
| 1.5/1.1 | 84.0 | 84.0 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 |
| 2/1.5 | 85.5 | 85.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 |
| 3/2.2 | 86.5 | 85.5 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 |
| 5/3.7 | 88.5 | 86.5 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 |
| 7.5/5.5 | 89.5 | 88.5 | 91.7 | 91.0 | 91 | 90.2 | 86.5 | 89.5 |
| 10/7.5 | 90.2 | 89.5 | 91.7 | 91.7 | 91 | 91.7 | 89.5 | 90.2 |
| 15/11 | 91.0 | 90.2 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 |
| 20/15 | 91.0 | 91.0 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 |
| 25/18.5 | 91.7 | 91.7 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 |
| 30/22 | 91.7 | 91.7 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 |
| 40/30 | 92.4 | 92.4 | 94.1 | 94.1 | 94.1 | 94.1 | 91.7 | 91.7 |
| 50/37 | 93.0 | 93.0 | 94.5 | 94.5 | 94.1 | 94.1 | 92.4 | 92.4 |
| 60/45 | 93.6 | 93.6 | 95.0 | 95.0 | 94.5 | 94.5 | 92.4 | 93.0 |
| 75/55 | 93.6 | 93.6 | 95.4 | 95.0 | 94.5 | 94.5 | 93.6 | 94.1 |
| 100/75 | 94.1 | 93.6 | 95.4 | 95.4 | 95.0 | 95.0 | 93.6 | 94.1 |
| 125/90 | 95.0 | 94.1 | 95.4 | 95.4 | 95.0 | 95.0 | 94.1 | 94.1 |
| 150/110 | 95.0 | 94.1 | 95.8 | 95.8 | 95.8 | 95.4 | 94.1 | 94.1 |
| 200/150 | 95.4 | 95.0 | 96.2 | 95.8 | 95.8 | 95.4 | 94.5 | 94.1 |
| 250/186 | 95.8 | 95.0 | 96.2 | 95.8 | 95.8 | 95.8 | 95.0 | 95.0 |
| 300/224 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 |
|
|
| 350/261 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 |
|
|
| 400/298 | 95.8 | 95.8 | 96.2 | 95.8 |
|
|
|
|
| 450/336 | 95.8 | 96.2 | 96.2 | 96.2 |
|
|
|
|
| 500/373 | 95.8 | 96.2 | 96.2 | 96.2 |
|
|
|
|
Minimum Nominal Full-Load Efficiencies of NEMA Design C and IEC Design H Motors at 60 Hz
| Motor Horsepower/ Standard Kilowatt Equivalent | Nominal Full‐Load Efficiency(%) | |||||
| 4 pole | 6 pole | 8 pole | ||||
| Enclosed | Open | Enclosed | Open | Enclosed | Open | |
| 1/.75 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 |
| 1.5/1.1 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 |
| 2/1.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 |
| 3/2.2 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 |
| 5/3.7 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 |
| 7.5/5.5 | 91.7 | 91.0 | 91 | 90.2 | 86.5 | 89.5 |
| 10/7.5 | 91.7 | 91.7 | 91 | 91.7 | 89.5 | 90.2 |
| 15/11 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 |
| 20/15 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 |
| 25/18.5 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 |
| 30/22 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 |
| 40/30 | 94.1 | 94.1 | 94.1 | 94.1 | 91.7 | 91.7 |
| 50/37 | 94.5 | 94.5 | 94.1 | 94.1 | 92.4 | 92.4 |
| 60/45 | 95.0 | 95.0 | 94.5 | 94.5 | 92.4 | 93.0 |
| 75/55 | 95.4 | 95.0 | 94.5 | 94.5 | 93.6 | 94.1 |
| 100/75 | 95.4 | 95.4 | 95.0 | 95.0 | 93.6 | 94.1 |
| 125/90 | 95.4 | 95.4 | 95.0 | 95.0 | 94.1 | 94.1 |
| 150/110 | 95.8 | 95.8 | 95.8 | 95.4 | 94.1 | 94.1 |
| 200/150 | 96.2 | 95.8 | 95.8 | 95.4 | 94.5 | 94.1 |
Minimum Nominal Full-Load Efficiencies of Fire Pump Electric Motors at 60 Hz
| Motor Horsepower/ Standard Kilowatt Equivalent | Nominal Full‐Load Efficiency (%) | |||||||
| 2 pole | 4 pole | 6 pole | 8 pole | |||||
| Enclosed | Open | Enclosed | Open | Enclosed | Open | Enclosed | Open | |
| 1/.75 | 75.5 |
|
82.5 | 82.5 | 80.0 | 80.0 | 74.0 | 74.0 |
| 1.5/1.1 | 82.5 | 82.5 | 84. | 84.0 | 85.5 | 84.0 | 77.0 | 75.5 |
| 2/1.5 | 84.0 | 84.0 | 84.0 | 84.0 | 86.5 | 85.5 | 82.5 | 85.5 |
| 3/2.2 | 85.5 | 84.0 | 87.5 | 86.5 | 87.5 | 86.5 | 84.0 | 86.5 |
| 5/3.7 | 87.5 | 85.5 | 87.5 | 87.5 | 87.5 | 87.5 | 85.5 | 87.5 |
| 7.5/5.5 | 88.5 | 87.5 | 89.5 | 88.5 | 89.5 | 88.5 | 85.5 | 88.5 |
| 10/7.5 | 89.5 | 88.5 | 89.5 | 89.5 | 89.5 | 90.2 | 88.5 | 89.5 |
| 15/11 | 90.2 | 89.5 | 91.0 | 91.0 | 90.2 | 90.2 | 88.8 | 89.5 |
| 20/15 | 90.2 | 90.2 | 91.0 | 91.0 | 90.2 | 91.0 | 89.5 | 90.2 |
| 25/18.5 | 91.0 | 91.0 | 92.4 | 91.7 | 91.7 | 91.7 | 89.5 | 90.2 |
| 30/22 | 91.0 | 91.0 | 92.4 | 92.4 | 91.7 | 92.4 | 91.0 | 91.0 |
| 40/30 | 91.7 | 91.7 | 93.0 | 93.0 | 93.0 | 93.0 | 91.0 | 91.0 |
| 50/37 | 92.4 | 92.4 | 93.0 | 93.0 | 93.0 | 93.0 | 91.7 | 91.7 |
| 60/45 | 93.0 | 93.0 | 93.6 | 93.6 | 93.6 | 93.6 | 91.7 | 92.4 |
| 75/55 | 93.0 | 93.0 | 94.1 | 94.1 | 93.6 | 93.6 | 93.0 | 93.6 |
| 100/75 | 93.6 | 93.0 | 94.5 | 94.1 | 94.1 | 94.1 | 93.0 | 93.6 |
| 125/90 | 94.5 | 93.6 | 94.5 | 94.5 | 94.1 | 94.1 | 93.6 | 93.6 |
| 150/110 | 94.5 | 93.6 | 95.0 | 95.0 | 95.0 | 94.5 | 93.6 | 93.6 |
| 200/150 | 95.0 | 94.5 | 95.0 | 95.0 | 95.0 | 94.5 | 94.1 | 93.6 |
| 250/186 | 95.4 | 94.5 | 95.0 | 95.4 | 95.0 | 95.4 | 94.5 | 94.5 |
| 300/224 | 95.4 | 95.0 | 95.4 | 95.4 | 95.0 | 95.4 |
|
|
| 350/261 | 95.4 | 95.0 | 95.4 | 95.4 | 95.0 | 95.4 |
|
|
| 400/298 | 95.4 | 95.4 | 95.4 | 95.4 |
|
|
|
|
| 450/336 | 95.4 | 95.8 | 95.4 | 95.8 |
|
|
|
|
| 500/373 | 95.4 | 95.8 | 95.8 | 95.8 |
|
|
|
|
EXCEPTION to Sections 1605.1(s)(2), 1605.1(s)(3), and 1605.1(s)(4) of this Article. The standards in Tables S-1, S-2 or S-3 of this Article do not apply to the following electric motors exempted by the Secretary, or any additional electric motors that the Secretary may exempt
(A) Air-over electric motors;
(B) Component sets of an electric motor;
(C) Liquid-cooled electric motors;
(D) Submersible electric motors; and
(E) Inverter-only electric motors.
Standards for Small Electric Motors
| Motor Horsepower/ Standard Kilowatt Equivalent | Minimum Average Full‐Load Efficiency | |||||
| Polyphase | Capacitor‐start capacitor‐run and capacitor‐start induction run Motors | |||||
| 6 poles | 4 poles | 2 poles | 6 poles | 4 poles | 2 poles | |
| 0.25/0.18 | 67.5 | 69.5 | 65.6 | 62.2 | 68.5 | 66.6 |
| 0.33/0.25 | 71.4 | 73.4 | 69.5 | 66.6 | 72.4 | 70.5 |
| 0.5/0.37 | 75.3 | 78.2 | 73.4 | 76.2 | 76.2 | 72.4 |
| 0.75/0.55 | 81.7 | 81.1 | 76.8 | 80.2 | 81.8 | 76.2 |
| 1.0/0.75 | 82.5 | 83.5 | 77.0 | 81.1 | 82.6 | 80.4 |
| 1.5/1.1 | 83.8 | 86.5 | 84.0 |
|
83.8 | 81.5 |
| 2.0/1.5 |
|
86.5 | 85.5 |
|
84.5 | 82.9 |
| 3.0/2.2 |
|
86.9 | 85.5 |
|
|
84.1 |
Standards for Federally Regulated Compressors Manufactured on or After January 10, 2025
| Equipment Class | Minimum Package Isentropic Efficiency† | ηRegr (package isentropic efficiency reference curve) |
d (Percentage Loss Reduction |
| Rotary, lubricated, air-cooled, fixed-speed compressor | ????egr + (1 - ????egr) * (d/100) | −0.00928 * ln2(.4719 * ??1) + 0.13911 * ln(.4719 * ??1) + 0.27110 | -15 |
| Rotary, lubricated, air-cooled, variable-speed compressor | ????egr + (1 - ????egr) * (d/100) | −0.01549 * ln2(.4719 * ??1) + 0.21573 * ln(.4719 * ??1) + 0.00905 | -10 |
| Rotary, lubricated, liquid-cooled, fixed-speed compressor | .02349 + ????egr + (1 - ????egr) * d/100) | −0.00928 * ln2(.4719 * ??1) + 0.13911 * ln(.4719 * ??1) + 0.27110 | -15 |
| Rotary, lubricated, liquid-cooled, variable-speed compressor | .02349 + ????egr + (1 - ????egr) * d/100) | −0.01549 * ln2(.4719 * ??1) + 0.21573 * ln(.4719 * ??1) + 0.00905 | -15 |
| Where V1 is the full-load actual volume flow rate of the compressor, in cubic feet per minute, as determined in accordance with the test procedure in section 1604(s) of this Article.
† For "fixed-speed compressor" equipment classes, the relevant Package Isentropic Efficiency is Full-load PackageIsentropic Efficiency. For "Variable-speed compressor" equipment classes, the relevant Package Isentropic Efficiency is Part-load Package Isentropic Efficiency. Both Full- and Part-Load Package Isentropic Efficiency are determined in accordance with the test procedure in section 1604(s) of this Article. | |||
Standards for Low-Voltage Dry-Type Distribution Transformers
| Single phase | Three phase | |||
| kVa | Efficiency (%)¹ | kVa | Efficiency (%)¹ | |
| 15 | 97.7 | 15 | 97.89 | |
| 25 | 98.0 | 30 | 98.23 | |
| 37.5 | 98.2 | 45 | 98.40 | |
| 50 | 98.3 | 75 | 98.60 | |
| 75 | 98.5 | 112.5 | 98.74 | |
| 100 | 98.6 | 150 | 98.83 | |
| 167 | 98.7 | 225 | 98.94 | |
| 250 | 98.8 | 300 | 99.02 | |
| 333 | 98.9 | 500 | 99.14 | |
|
|
|
750 | 99.23 | |
|
|
|
1000 | 99.28 | |
| ¹ All efficiency values are at 35 percent of nameplate-rated load, determined according to the DOE Test Method for Measuring the Energy Consumption of distribution Transformers under Appendix A to subpart K of 10 C.F.R. part 431. | ||||
Standards for Liquid-Immersed Distribution Transformers
| Single phase | Three phase | ||
| kVA | Efficiency (%)¹ | kVA | Efficiency (%)¹ |
| 10 | 98.70 | 15 | 98.65 |
| 15 | 98.82 | 30 | 98.83 |
| 25 | 98.95 | 45 | 98.92 |
| 37.5 | 99.05 | 75 | 99.03 |
| 50 | 99.11 | 112.5 | 99.11 |
| 75 | 99.19 | 150 | 99.16 |
| 100 | 99.25 | 225 | 99.23 |
| 167 | 99.33 | 300 | 99.27 |
| 250 | 99.39 | 500 | 99.35 |
| 333 | 99.43 | 750 | 99.40 |
| 500 | 99.49 | 1000 | 99.43 |
| 667 | 99.52 | 1500 | 99.48 |
| 833 | 99.55 | 2000 | 99.51 |
|
|
|
2500 | 99.53 |
| ¹ All efficiency values are at 50 percent of nameplate-rated load, determined according to the DOE Test Method for Measuring the Energy Consumption of distribution Transformers under Appendix A to subpart K of 10 C.F.R. part 431. | |||
Table T-5
Standards for Medium-Voltage Dry-Type Distribution Transformers
Manufactured On or After January 1, 2016
| Single phase | Three phase | ||||||
| BIL | BIL | ||||||
| kVA | 20‐45 kV efficiency¹ (%) | 46‐95 kV efficiency¹ (%) | ≥ 96 kV efficiency¹ (%) | BIL kVA | 20‐45 kV efficiency¹ (%) | 46‐95 kV efficiency¹ (%) | ≥ 96 kV efficiency¹ (%) |
| 15 | 98.10 | 97.86 |
|
15 | 97.50 | 97.18 |
|
| 25 | 98.33 | 98.12 |
|
30 | 97.90 | 97.63 |
|
| 37.5 | 98.49 | 98.30 |
|
45 | 98.10 | 97.86 |
|
| 50 | 98.60 | 98.42 |
|
75 | 98.33 | 98.13 |
|
| 75 | 98.73 | 98.57 | 98.53 | 112.5 | 98.52 | 98.36 |
|
| 100 | 98.82 | 98.67 | 98.63 | 150 | 98.65 | 98.51 |
|
| 167 | 98.96 | 98.83 | 98.80 | 225 | 98.82 | 98.69 | 98.57 |
| 250 | 99.07 | 98.95 | 98.91 | 300 | 98.93 | 98.81 | 98.69 |
| 333 | 99.14 | 99.03 | 98.99 | 500 | 99.09 | 98.99 | 98.89 |
| 500 | 99.22 | 99.12 | 99.09 | 750 | 99.21 | 99.12 | 99.02 |
| 667 | 99.27 | 99.18 | 99.15 | 1000 | 99.28 | 99.20 | 99.11 |
| 833 | 99.31 | 99.23 | 99.20 | 1500 | 99.37 | 99.30 | 99.21 |
|
|
|
|
|
2000 | 99.43 | 99.36 | 99.28 |
|
|
|
|
|
2500 | 99.47 | 99.41 | 99.33 |
| ¹ All efficiency values are at 50 percent of nameplate-rated load, determined according to the DOE Test Method for Measuring the Energy Consumption of distribution Transformers under Appendix A to subpart K of 10 C.F.R. part 431 | |||||||
Standards for Class A External Power Supplies
| Active Mode | |
| Nameplate Output | Required efficiency (decimal equivalent of a percentage) |
| Less than 1 watt | 0.5 times the Nameplate Output |
| From 1 watt to not more than 51 watts | The sum of 0.09 times the Natural Logarithm of the Nameplate Output and 0.5 |
| Greater than 51 watts | 0.85 |
| Not more than 250 watts | No-Load Mode |
| Maximum Consumption | |
| 0.5 Watts | |
Standards for Direct Operation External Power Supplies
| Power Supply Type | Nameplate Output Power (Pout) | Minimum Average Efficiency in Active Mode* | Maximum Power in No-Load Mode [W] |
| Single-Voltage External AC-DC Power Supply, Basic Voltage | Pout ≤ 1 W | ≥ 0.5 x Pout + 0.16 | ≤ 0.100 |
| 1 W ≤ Pout ≤ 49 W | ≥ 0.071 x In(Pout) - 0.0014 x Pout +0.67 | ≤ 0.100 | |
| 49 W ≤ Pout ≤ 250 W | ≥ 0.880 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Single-Voltage External AC-DC Power Supply, Low-Voltage | Pout ≤ 1 W | ≥ 0.517 x Pout + 0.87 | ≤ 0.100 |
| 1 W ≤ Pout ≤ 49 W | ≥ 0.834 x In(Pout) - 0.0014 x Pout +0.609 | ≤ 0.100 | |
| 49 W ≤ Pout ≤ 250 W | ≥ 0.87 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Single-Voltage External AC-AC Power Supply, Basic Voltage | Pout ≤ 1 W | ≥ 0.5 x Pout + 0.16 | ≤ 0.210 |
| 1 W ≤ Pout ≤ 49 W | ≥ 0.071 x In(Pout) - 0.0014 x Pout +0.67 | ≤ 0.210 | |
| 49 W < Pout ≤ 250 W | ≥ 0.880 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Single-Voltage External AC-AC Power Supply, Low-Voltage | Pout ≤ 1 W | ≥ 0.517 x Pout + 0.87 | ≤ 0.210 |
| 1 W ≤ Pout ≤ 49 W | ≥ 0.834 x In(Pout) - 0.0014 x Pout +0.609 | ≤ 0.210 | |
| 49 W ≤ Pout ≤ 250 W | ≥ 0.87 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Multiple-Voltage External Power Supply | Pout ≤ 1 W | ≥ 0.497 x Pout + 0.067 | ≤ 0.300 |
| 1 W < Pout ≤ 49 W | ≥ 0.075 x In(Pout) +0.561 | ≤ 0.300 | |
| Pout > 49W | ≥ 0.860 | ≤ 0.300 | |
| *Expressed as a decimal | |||
Standards for All External Power Supplies Manufactured On or After February 10, 2016
| Operation EPS Type | Class A EPS | Non-Class A EPS |
| Direct Operation EPS | Level VI: 10 C.F.R. 430.32 (w)(1)(ii) | Level VI: 10 C.F.R. 430.32 (w)(1)(ii) |
| Indirect Operation EPS | Level VI: 10 C.F.R. 430.32 (w)(1)(i) | No standards |
See Section 1605.3(v) of this Article for energy efficiency standards for computers, computer monitors, televisions, signage displays, and consumer audio and video equipment.
Standards for Federally Regulated Battery Chargers Manufactured on or after June 13, 2018
(2) Federally Regulated Uninterruptible Power Supplies (UPSs) Manufactured on and after January 10, 2022. Federally regulated uninterruptible power supplies manufactured on or after January 10, 2022, that utilize a NEMA 1-15P or 5-15P input plug and have an AC output shall have an average load adjusted efficiency that meets or exceeds the values shown in Table W-2 based on the rated output power (Prated) of the UPS.
Standards for Federally Regulated Uninterruptible Power Supplies (UPS) Manufactured on or after January 10, 2022
| Battery charger product class | Rated output power | Minimum efficiency |
| 10a (VFD UPSs) | 0 W < Prated ≤ 300 W | −1.20E-06 * P2rated + 7.17E-04 * Prated + 0.862 |
| 300 W < Prated ≤ 700 W | −7.85E-08 * P2rated + 1.01E-04 * Prated + 0.946 | |
| Prated > 700 W | −7.23E-09 * P2rated + 7.52E-06 * Prated + 0.977 | |
| 10b (VI UPSs) | 0 W < Prated ≤ 300 W | −1.20E-06 * P2rated + 7.19E-04 * Prated + 0.863 |
| 300 W < Prated ≤ 700 W | −7.67E-08 * P2rated + 1.05E-04 * Prated + 0.947 | |
| Prated > 700 W | −4.62E-09 * P2rated + 8.54E-06 * Prated + 0.979 | |
|
10c (VFI UPSs) | 0 W < Prated ≤ 300 W | −3.13E-06 * P2rated + 1.96E-03 * Prated + 0.543 |
| 300 W < Prated ≤ 700 W | −2.60E-07 * P2rated + 3.65E-04 * Prated + 0.764 | |
| Prated > 700 W | −1.70E-08 * P2rated + 3.85E-05 * Prated + 0.876 |
C.F.R., Title 10, section 429.39(a)
C.F.R., Title 10, section 429.44
C.F.R., Title 10, section 429.59
C.F.R., Title 10, part 430, subpart B, appendix AA
C.F.R., Title 10, sections 430.23(a) (Appendix A to subpart B of part 430)
C.F.R., Title 10, sections 430.23(b) (Appendix B to subpart B of part 430)
C.F.R., Title 10, section 430.32(c)
C.F.R., Title 10, section 430.32(d)
C.F.R., Title 10, section 430.32(w)(1)
C.F.R., Title 10, sections 431.63
C.F.R., Title 10, sections 431.66(d)(2)(i) through (iii)
C.F.R., Title 10, section 431.110
C.F.R., Title 10, section 431.324
C.F.R., Title 10, section 431.326(b)(3)
C.F.R., Title 10, section 431.462
C.F.R., Title 10, part 431, subpart K, Appendix A
C.F.R., Title 10, section 431.465(c)(6)
C.F.R., Title 10, part 431, subpart Y, Appendix A, Section II.B
C.F.R., Title 10, part 50, “Domestic Licensing of Production and Utilization Facilities”
| Copies available from: | Superintendent of Documents | ||
|
|
| ||
|
|
U.S. Government Printing Office | ||
|
|
Washington, DC 20402 | ||
|
|
http://www.ecfr.gov | ||
|
|
| ||
| UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) | |||
|
|
| ||
|
|
EPA “External ‘Power Supply International Efficiency Marking Protocol” | ||
|
| |||
|
|
| ||
| Copies available from: | US EPA | ||
|
|
Climate Protection Partnership | ||
|
|
ENERGY STAR Programs Hotline & | ||
|
|
Distribution | ||
|
|
(MS- 6202 J) | ||
|
|
1200 Pennsylvania Ave NW | ||
|
|
Washington, ‘DC 20460 | ||
|
|
www.energystar.gov | ||
|
|
| ||
| AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI) | |||
|
|
| ||
| AHRI 1200-2006 | Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | ||
|
|
| ||
| Copies available from: | Air-Conditioning, Heating and | ||
|
|
Refrigeration Institute (AHRI) | ||
|
|
2111 Wilson Blvd, Suite 500 | ||
|
|
Arlington, VA 22201 | ||
|
|
Phone: (703) 524-8800 | ||
|
|
FAX: (703) 562-1942 | ||
|
|
http://www.ahrinet.org | ||
|
|
| ||
| AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) | |||
|
|
| ||
| ANSI C78.5 | Standard for Electric Lamps - Specifications for Performance of Self-Ballasted Compact Fluorescent Lamps | ||
|
|
| ||
| Copies available from: | American National Standards Institute | ||
|
|
1819 L Street, NW, 6th Floor | ||
|
|
Washington, DC 2003 6 | ||
|
|
www.ansi.org | ||
|
|
Phone: (202) 293-8020 | ||
|
|
FAX: (202) 293-9287 | ||
|
|
| ||
| ILLUMINATING ENGINGEERING SOCIETY (IES) | |||
|
|
| ||
| IES LM-65 | Life Testing of Compact Fluorescent Lamps | ||
|
|
| ||
| Copies available from: | Illuminating Engineering Society | ||
|
|
120 Wall Street, 17th Floor | ||
|
|
New York, NY 10005-4001 | ||
|
|
www.ies.org | ||
|
|
Phone: (212) 248-5000 | ||
|
|
FAX: (212) 248-5017/18 | ||
|
|
| ||
| NATIONAL ELECTRIC CODE (NEC) | |||
| NFPA 70 (2002) | National Electrical Code section 410.4(A) | ||
|
|
| ||
| Copies available from: | National Fire Protection Association | ||
|
|
1 Batterymarch Park | ||
|
|
Quincy, MA 02169-7471 | ||
|
|
www.nfpa.org | ||
|
|
Phone: (617) 770-3000 | ||
|
|
FAX: (617) 770-0700 | ||
|
|
| ||
| NATIONAL ELECTRIC ‘MANUFACTURERS ASSOCIATION (NEMA) | |||
|
|
| ||
| NEMA Standard TP-1-2002, Table 4-2 | Guide for Determining Energy Efficiency of Distribution ‘Transformers | ||
|
|
| ||
| Copies available from: | National Electric Manufacturers Association | ||
|
|
1300 N. 17th Street, Suite 1847 | ||
|
|
Rosslyn, VA 22209 | ||
|
|
www.nema.org | ||
|
|
Phone: (703) 841-3200 | ||
|
|
FAX: (703) 81-3300 | ||
|
|
| ||
| UNDERWRITERS LABS (UL) | |||
|
|
| ||
| UL 1029-2001 | Standard for High-Intensity-Discharge Lamp Ballasts | ||
|
|
| ||
| Copies available from: | Underwriters Laboratories, Inc. | ||
|
|
333 Pfingsten Road | ||
|
|
Northbrook, IL 60062-2096 | ||
|
|
www.ul.com | ||
|
|
Phone: (847) 272-8800 | ||
|
|
FAX: (847) 272-8129 | ||
Note: Authority cited: Sections 25213, 25218(e), 25401.9, 25402(a)-25402(c), and 25960, Public Resources Code; and sections 16, 26, and 30, Governor's Exec. Order No. B-29-15 (April 1, 2015). Reference: Sections 25216.5(d), 25401.9, 25402(a)-25402(c), and 25960, Public Resources Code; and Section 16, Governor's Exec. Order No. B-29-15 (April 1, 2015).
HISTORY
1. New section filed 10-28-2002; operative 11-27-2002 (Register 2002, No. 44).
2. Amendment of subsection (c)(1) Table C-2 filed 4-1-2003 as an emergency; operative 4-1-2003 (Register 2003, No. 14). A Certificate of Compliance must be transmitted to OAL by 7-30-2003 or emergency language will be repealed by operation of law on the following day.
3. Certificate of Compliance as to 4-1-2003 order transmitted to OAL 7-8-2003 and filed 8-19-2003 (Register 2003, No. 34).
4. Amendment of subsection (p)(1), new subsection (p)(4) and subsection renumbering filed 7-29-2004; operative 8-28-2004 (Register 2004, No. 31).
5. Amendment filed 3-16-2005; operative 4-15-2005 (Register 2005, No. 11).
6. Repealer of subsection (c)(2), subsection renumbering, amendment of subsection (f)(1), repealer of Table F-2, renumbering of tables, including amendment of newly designated Table F-2 and F-3 headings, and amendment of subsections (f)(2), (k)-(k)(3) and (u) and list of incorporated documents filed 12-30-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).
7. Amendment of Note filed 12-14-2006; operative 12-14-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 50).
8. Amendment filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
9. Amendment of subsection (l) and new subsections (l)(1)-(2) filed 10-26-2012; operative 1-1-2013 (Register 2012, No. 43).
10. Amendment filed 4-22-2014; operative 7-1-2014 (Register 2014, No. 17).
11. Amendment of subsection (h)(1) (including amendment of Table H-1), new subsection (h)(5), amendment of subsection (i) (including repealer of Table I) and amendment of Note filed with the Secretary of State by the Office of Administrative Law on 5-15-2015. Submitted to OAL for printing only pursuant to Governor's Executive Order No. B-29-15 (4-1-2015); operative 5-15-2015 (Register 2015, No. 20).
12. Amendment of subsections (h)(1) and (h)(5) and list of incorporated documents filed 8-20-2015; operative 8-20-2015 pursuant to Governor's Executive Order No. B-29-15, directive 30 (4-1-2015) (Register 2015, No. 34).
13. Amendment of subsections (a)(1), (a)(2)(A) and (a)(3), new subsections (a)(3)(A)-(C), amendment of subsection (a)(4)(C), new subsections (a)(4)(C)(i)-(ii), amendment of subsection (a)(6), repealer of subsection (b)(2)(A), subsection relettering, amendment of newly designated subsection (b)(2)(A) and subsections (c)(1)-(c)(1)(A), new subsection (c)(4), amendment of subsections (e)(1), (f)(2), (j) and (k)(2)(A)2.b.-c., new subsection (k)(2)(A)2.d., repealer and new subsections (n)(2)-(n)(3), amendment of subsections (p)(3) and (r)(2), new subsections (u)(1)(D)-(u)(1)(D)2. and amendment of subsection (w) filed 6-30-2016; operative 7-1-2016 pursuant to Government Code section 11343.4(b)(3) (Register 2016, No. 27).
14. Amendment of subsections within subsection (k), including renumbering of tables K-1 through K-8 to K-2 through K-9, filed 11-1-2016; operative 1-1-2017 (Register 2016, No. 45).
15. Amendment of subsection (v) filed 8-22-2017; operative 10-1-2017 (Register 2017, No. 34).
16. Amendment filed 9-26-2018; operative 10-1-2018 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 39).
17. Editorial correction of subsections (a)(2)(C)2. and (c)(1)(A), Table O and subsection (w)(1) (Register 2018, No. 45).
18. Editorial correction of Table E-3 (Register 2018, No. 48).
19. Change without regulatory effect amending subsections (d)(4)-(d)(4)(A), Table F-4, subsections (g)(6)(C) and (j)(2)(D)2. and heading for Table K-3 filed 3-18-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 12).
20. New subsection (d)(5), subsection renumbering and amendment of newly designated subsection (d)(6) filed 3-18-2019; operative 3-18-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 12).
21. Amendment of subsection (s)(7) filed 6-10-2019; operative 6-10-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 24).
22. Change without regulatory effect amending Table C-3 filed 7-24-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 30).
23. New subsection (x) and amendment of Note filed 10-7-2019; operative 10-1-2020 pursuant to Government Code section 11343.4(b)(2) and Public Resources Code section 25402(c)(1) (Register 2019, No. 41).
24. Change without regulatory effect amending subsection (g)(6)(B)2. filed 12-12-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 50).
25. Amendment of subsections and tables within subsection (k) filed 12-24-2019; operative 1-1-2020 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 52).
26. Amendment of subsections (g) and (g)(6)(A), new subsections (g)(7)-(g)(7)(E), subsection renumbering and amendment of newly designated subsection (g)(8) filed 9-21-2020; operative 1-1-2021 (Register 2020, No. 39). Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20 and an additional 60 calendar days pursuant to Executive Order N-66-20.
27. Amendment of subsections (a)(1)(A) and (a)(7), repealer of subsection (a)(7)(B), subsection relettering, amendment of Table C-5, subsection (d)(1), Table D-4, subsections (d)(2) and (d)(4), Table D-11, subsections (d)(5)-(6), Table F-5, Table G-2, subsections (j)(2)(D), (k)(2), (k)(2)(B), (k)(3)(B), (k)(4)(B), (k)(5)(B) and (l), repealer of subsections (l)(1)-(2), amendment of subsections (n)(2)(C) and (s)(4), amendment of Table T-4 and subsection (x) filed 3-16-2021; operative 3-16-2021 pursuant to Government Code section 11343.4(b)(3) (Register 2021, No. 12). (Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20.)
28. Change without regulatory effect amending subsections (g)(7)(A) and (u)(1) - Table U-1 filed 7-12-2021 pursuant to section 100, title 1, California Code of Regulations (Register 2021, No. 29).
29. Amendment filed 7-18-2024; operative 7-18-2024 pursuant to Government Code section 11343.4(b)(3) (Register 2024, No. 29).
30. Change without regulatory effect amending subsections (p)(1)-(2) and (r)(2) filed 6-12-2025 pursuant to section 100, title 1, California Code of Regulations (Register 2025, No. 33)
This database is current through 11/6/26 Register 2026, No. 45
Cal. Admin. Code tit. 20, § 1605.1, 20 CA ADC § 1605.1